首页> 外文期刊>The Science of the Total Environment >Personal exposure monitoring of PM_(2.5) in indoor and outdoor microenvironments
【24h】

Personal exposure monitoring of PM_(2.5) in indoor and outdoor microenvironments

机译:室内和室外微环境中PM_(2.5)的个人暴露监测

获取原文
获取原文并翻译 | 示例
           

摘要

Adverse health effects from exposure to air pollution are a global challenge and of widespread concern. Recent high ambient concentration episodes of air pollutants in European cities highlighted the dynamic nature of human exposure and the gaps in data and knowledge about exposure patterns. In order to support health impact assessment it is essential to develop a better understanding of individual exposure pathways in people's everyday lives by taking account of all environments in which people spend time. Here we describe the development validation and results of an exposure method applied in a study conducted in Scotland. A low-cost particle counter based on light-scattering technology - the Dylos 1700 was used. Its performance was validated in comparison with equivalent instruments (TEOM-FDMS) at two national monitoring network sites (R~2 = 0.9 at a rural background site, R~2 = 0.7 at an urban background site). This validation also provided two functions to convert measured PNCs into calculated particle mass concentrations for direct comparison of concentrations with equivalent monitoring instruments and air quality limit values. This study also used contextual and time-based activity data to define six microenvironments (MEs) to assess everyday exposure of individuals to short-term PM_(2.5) concentrations. The Dylos was combined with a GPS receiver to track movement and exposure of individuals across the MEs. Seventeen volunteers collected 35 profiles. Profiles may have a different overall duration and structure with respect to times spent in different MEs and activities undertaken. Results indicate that due to the substantial variability across and between MEs, it is essential to measure near-complete exposure pathways to allow for a comprehensive assessment of the exposure risk a person encounters on a daily basis. Taking into account the information gained through personal exposure measurements, this work demonstrates the added value of data generated by the application of low-cost monitors.
机译:暴露于空气污染中对健康的不利影响是一项全球挑战,并引起广泛关注。欧洲城市近来空气污染物的高环境浓度事件突显了人类暴露的动态性质以及有关暴露模式的数据和知识方面的差距。为了支持健康影响评估,有必要通过考虑人们花费时间的所有环境来更好地了解人们日常生活中的个体接触途径。在这里,我们描述了在苏格兰进行的一项研究中所采用的曝光方法的开发验证和结果。使用基于光散射技术的低成本粒子计数器-Dylos 1700。与两个国家监测网站点的等效仪器(TEOM-FDMS)相比,其性能得到了验证(农村背景站点的R〜2 = 0.9,城市背景站点的R〜2 = 0.7)。该验证还提供了两个功能,可将测得的PNC转换为计算出的颗粒质量浓度,以便直接将浓度与等效的监测仪器和空气质量极限值进行比较。这项研究还使用上下文和基于时间的活动数据来定义六个微环境(ME),以评估个人每天短期暴露在PM_(2.5)浓度下的情况。 Dylos与GPS接收器结合使用,可以跟踪个体在ME中的移动和暴露情况。 17名志愿者收集了35个个人资料。关于在不同的ME和所进行的活动中花费的时间,配置文件可能具有不同的总体持续时间和结构。结果表明,由于各监测系统之间和监测系统之间存在很大差异,因此必须测量接近完全的接触途径,以便全面评估一个人每天所面临的接触风险。考虑到通过个人接触测量获得的信息,这项工作证明了通过使用低成本监测仪产生的数据的附加值。

著录项

  • 来源
    《The Science of the Total Environment》 |2015年第1期|383-394|共12页
  • 作者单位

    NERC Centre for Ecology & Hydrology (CEH), Bush Estate, Penicuik, Midlothian EH26 0QB, United Kingdom,Geography, College of Life & Environmental Sciences, University of Exeter, Amory Building, Rennes Drive, Exeter EX4 4RJ, United Kingdom,Institute of Occupational Medicine, Edinburgh, Research Avenue North, Riccarton EH14 4AP, United Kingdom;

    NERC Centre for Ecology & Hydrology (CEH), Bush Estate, Penicuik, Midlothian EH26 0QB, United Kingdom,European Centre for Environment and Human Health (ECEHH), University of Exeter Medical School, Knowledge Spa, Royal Cornwall Hospital, Truro, Cornwall TR1 3HD, United Kingdom;

    School of Geographical Sciences, University of Bristol, University Rd, Bristol BS8 1SS, United Kingdom;

    Scottish Centre for Indoor Air, Division of Applied Health Sciences, University of Aberdeen, Aberdeen AB25 2ZD, United Kingdom,Scottish Centre for Indoor Air, Institute of Occupational Medicine, Edinburgh, Research Avenue North, Riccarton EH14 4AP, United Kingdom;

    NERC Centre for Ecology & Hydrology (CEH), Bush Estate, Penicuik, Midlothian EH26 0QB, United Kingdom;

    NERC Centre for Ecology & Hydrology (CEH), Bush Estate, Penicuik, Midlothian EH26 0QB, United Kingdom;

    NERC Centre for Ecology & Hydrology (CEH), Bush Estate, Penicuik, Midlothian EH26 0QB, United Kingdom;

    University of Edinburgh, School of Chemistry, Joseph Black Building, West Mains Road, Edinburgh EH9 3FJ, United Kingdom;

    Bureau Veritas, 5th Floor, 66 Prescot Street, London E1 8HG, United Kingdom;

    University of Edinburgh, School of Chemistry, Joseph Black Building, West Mains Road, Edinburgh EH9 3FJ, United Kingdom;

    NERC Centre for Ecology & Hydrology (CEH), Bush Estate, Penicuik, Midlothian EH26 0QB, United Kingdom,University of Edinburgh, School of Chemistry, Joseph Black Building, West Mains Road, Edinburgh EH9 3FJ, United Kingdom;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Air pollution; GPS; Paniculate matter; Particle counter; Personal exposure;