首页> 外文期刊>Romanian journal of physics >THE INFLUENCE OF COLLIMATORS ON THE FOCUSED ACOUSTIC BEAM
【24h】

THE INFLUENCE OF COLLIMATORS ON THE FOCUSED ACOUSTIC BEAM

机译:收藏家对聚焦声束的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

In this paper are presented the reflected acoustic pressure distributions from a target reflector using two acoustic systems. Use of acoustic systems consists of an unfocused planar transducer to which is attached a spherical or cylindrical lens (TL system). After illustrating, through 3D histograms, the point or line focused acoustic beam, a collimator with a circular aperture was attached to emphasize focused systems (TLC).The effects of collimation on the acoustic pressure distribution for the two systems is shown for the variable TLC system-reflector distances. Collimator sizes, lenses and planar transducer characteristics are also presented in this paper. An emphasized focusing is obtained by placing the aperture at variable distances from the TL system. Experiments were made using an unfocused transducer for 2 MHz and 24 mm diameter and SONIC 137 ULTRA ultrasonic device of the Stav-eley Company. The principal purpose of the paper was to obtain an improved understanding of how collimators modify the acoustic beam of a transducer.
机译:本文介绍了使用两个声学系统从目标反射器反射的声压分布。声学系统的使用包括未聚焦的平面换能器,在该换能器上连接了球面或柱面透镜(TL系统)。通过3D直方图说明点或线聚焦声束后,连接了具有圆形孔径的准直仪以增强聚焦系统(TLC)。对于可变TLC,示出了准直对两个系统的声压分布的影响系统反射器距离。本文还将介绍准直器的尺寸,透镜和平面传感器的特性。通过将光圈放置在距TL系统可变的距离处,可以得到增强的聚焦。使用Stav-eley公司的2 MHz和24 mm直径的非聚焦换能器以及SONIC 137 ULTRA超声设备进行实验。本文的主要目的是为了更好地理解准直器如何改变换能器的声束。