Backscattering experiments to detect lower-hybrid (LH) waves have been performed in Alcator C-Mod, using the two modified channels (60 GHz and 75 GHz) of an ordinary-mode reflectometry system with newly developed spectral recorders that can continuously monitor spectral power at a target frequency. The change in the baseline of the spectral recorder during the LH wave injection is highly correlated to the strength of the X-mode non-thermal electron cyclotron emission. In high density plasmas where an anomalous drop in the lower hybrid current drive efficiency is observed, the observed backscattered signals are expected to be generated near the last closed flux surface, demonstrating the presence of LH waves within the plasma. This experimental technique can be useful in identifying spatially localized LH electric fields in the periphery of high-density plasmas.
机译:已经在Alcator C-Mod中进行了反向散射实验,以检测低杂波(LH),使用了具有新开发的频谱记录仪的普通模式反射测量系统的两个修改的通道(60 GHz和75 GHz),该记录仪可以连续监控频谱功率以目标频率。在LH波注入过程中,光谱记录仪基线的变化与X模非热电子回旋辐射的强度高度相关。在观察到较低的混合电流驱动效率出现异常下降的高密度等离子体中,观察到的反向散射信号有望在最后一个闭合通量表面附近产生,这表明等离子体中存在LH波。此实验技术可用于识别高密度等离子体外围中的空间局部LH电场。