The Courant-Friedrichs-Lewy (CFL) criterion for the stability of numerical schemes is herein investigated at the conservative interface that divides rotating grids embedded within fixed grids. This issue is of specific interest to correctly assess the power coefficient and the energy production of vertical-axis wind turbines (VAWTs). The CFL number is here manipulated in a convenient form to tackle rotating grids; this manipulation discloses the dependence of the CFL number from the angular location of rotating grid elements and also from the tip speed ratio of the rotating grid. An upper bound of the CFL number that does not depend on the angular location of the rotating grid element is derived. The angular marching step has dramatic effects on the accuracy of results and strongly affects the calculation of the most important integral property (the power coefficient); however, local quantities are affected to a lesser extent and this fact is misleading. Large errors are generated if the angular marching step is too coarse or, in other words, if the CFL criterion is violated. Angular marching steps as small as only 1° do not warrant accurate results, particularly for very small tip speed ratios and fine spatial discretizations. It is found in this study that rotating grids call for a more restrictive (lower) bound (e.g., CFL number less than 0.15) as compared with the literature criterion. This restriction prompts severe limitations to obtain trustable results from numerical simulations of VAWTs.
机译:本文在保守接口处研究了数值方案稳定性的Courant-Friedrichs-Lewy(CFL)准则,该保守接口划分了嵌入固定网格内的旋转网格。为了正确评估垂直轴风力涡轮机(VAWT)的功率系数和能量产生,特别需要关注此问题。 CFL编号在此处以方便的形式进行处理,以应对旋转的网格;该操作公开了CFL数与旋转栅格元件的角位置以及旋转栅格的尖端速度比之间的关系。得出不依赖于旋转栅格元素的角位置的CFL数的上限。角行进步骤对结果的准确性有显着影响,并极大地影响最重要的积分特性(功率系数)的计算。但是,本地数量受到的影响较小,而且这个事实具有误导性。如果角度行进步骤过于粗糙,或者换言之,如果违反了CFL标准,则会产生较大的误差。仅小至1°的角行进步骤就不能保证获得准确的结果,特别是对于极小的尖端速度比和精细的空间离散而言。在这项研究中发现,与文献标准相比,旋转网格要求更严格的(较低的)界限(例如,CFL数小于0.15)。该限制提示了严格的限制,以便从VAWT的数值模拟中获得可信的结果。

著录项

  • 来源
    《Renewable energy》 |2014年第2期|53-62|共10页
  • 作者单位

    Department of Industrial Engineering, University of Trento, Via Mesiano, 77,1-38123 Trento, Italy;

    Department of Industrial Engineering, University of Padua, Via Venezia, 1,1-35131 Padua, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Courant-Friedrichs-Lewy; Darrieus; Rotating grid; Rotating ring; VAWT;