首页> 外文期刊>Renewable energy >An hourly simulation method for the energy performance of an office building served by a ground-coupled heat pump system
【24h】

An hourly simulation method for the energy performance of an office building served by a ground-coupled heat pump system

机译:地面耦合热泵系统为办公大楼提供的每小时能耗模拟方法

获取原文
获取原文并翻译 | 示例
           

摘要

Ground heat exchangers are key component of ground-coupled heat pump systems, and their thermal response is therefore very important for ground-coupled heat pump system design and operation. This paper proposes a new hourly simulation method, and uses it to study the performance improvement potential for the ground-coupled heat pump system. First, with an effective U-pipe shank spacing determined by the calculated and measured borehole thermal resistance, a reasonable and accurate fluid temperature prediction method is developed, and the hourly energy performance simulation method is also proposed accordingly with the Fast Fourier Transform superposition algorithm. This hourly simulation method is validated using experimental data collected from a well-designed ground-coupled heat pump experiment platform, which shows that the maximum absolute error for the predicted fluid temperature is smaller than 1.04 degrees C. Second, using the proposed hourly simulation method, a framework for the energy performance simulation of an office building served by the ground-coupled heat pump system is developed. Impact factors on ground-coupled heat pump system performance are systematically analyzed using this simulation method, and the results show that performance can be improved with shorter operation schedules and lower heat fluxes. (C) 2018 Elsevier Ltd. All rights reserved.
机译:地面热交换器是地面耦合热泵系统的关键组件,因此它们的热响应对于地面耦合热泵系统的设计和运行非常重要。本文提出了一种新的每小时模拟方法,并将其用于研究地面耦合热泵系统的性能改进潜力。首先,通过计算和测量的井眼热阻确定有效的U形管柄间距,开发了一种合理,准确的流体温度预测方法,并据此提出了快速傅立叶变换叠加算法的每小时能量性能模拟方法。使用从精心设计的地面耦合热泵实验平台收集的实验数据验证了此每小时模拟方法,该数据表明预测流体温度的最大绝对误差小于1.04摄氏度。第二,使用建议的每小时模拟方法,开发了一个由地面耦合热泵系统服务的办公楼能源性能模拟的框架。利用该仿真方法对地面耦合热泵系统性能的影响因素进行了系统分析,结果表明,可以通过缩短运行时间和降低热通量来提高性能。 (C)2018 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号