DOSE CONVERSION COEFFICIENTS FOR ELECTRON EXPOSURE OF THE HUMAN EYE LENS: CALCULATIONS INCLUDING A WHOLE BODY PHANTOM

机译:人眼透镜电子暴露的剂量转换系数:包括整个人体幻影的计算

获取原文
获取原文并翻译 | 示例

摘要

In this work, conversion coefficients from electron fluence to absorbed dose to the eye lens were calculated using Monte Carlo simulations based on a detailed stylised eye model and a very simple but whole body phantom. These data supersede and complement data published earlier based on the simulation of only a single stylised eye. The new data differ from the old ones by not more than 3, 4, 7 and 16 % for angles of radiation incidence of α=0°, 15°, 30° and 45°, respectively, due to the inclusion of the whole body phantom. The data presented in the present work also complement those of a recent report of the International Commission on Radiological Protection (ICRP) (ICRP Publication 116), where conversion coefficients from electron fluence to absorbed dose to the lens of the eye are shown for solely 0°, 180° and isotropic radiation incidence (but for a much broader range of energies). In this article, values are provided for angles of incidence of 0° up to 180° in steps of 15° and for rotational geometry; no systematic deviation was observed from the values given in ICRP Publication 116 for 0° (based on the application of a bare eye) and 180° (based on the application of a voxel whole body phantom). Data are given for monoenergetic electrons from 0.1 up to 10 MeV and for a broad parallel beam geometry in vacuum.
机译:在这项工作中,基于详细的程式化眼睛模型和非常简单但完整的人体模型,使用蒙特卡罗模拟计算了从电子通量到吸收剂量的转换系数。这些数据取代和补充了先前基于仅一只风格化眼睛的模拟而发布的数据。新数据与旧数据的差异不超过3%,4%,7%和16%,这是因为辐射的入射角分别为α= 0°,15°,30°和45°,这是因为包括了整个身体幻影。本工作中提供的数据还补充了国际放射防护委员会(ICRP)的最新报告(ICRP出版物116)中的数据,其中仅显示了从电子注量到吸收到眼睛晶状体的剂量的转换系数0 °,180°和各向同性辐射入射(但适用于更大范围的能量)。在本文中,提供了0°到180°的入射角(以15°为步长)的值以及旋转几何形状的值;对于0°(基于裸眼的应用)和180°(基于体素全身模型的应用),未与ICRP出版物116中给出的值发生系统性偏差。给出了从0.1 MeV到10 MeV的单能电子以及在真空中较宽的平行束几何结构的数据。

著录项

  • 来源
    《Radiation Protection Dosimetry 》 |2013年第2期| 224-235| 共12页
  • 作者

    R. Behrens;

  • 作者单位

    Physikalisch-Technische Bundesanstalt, Bundesallee 100, D-38116 Braunschweig, Germany;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号