首页> 美国卫生研究院文献>Journal of Radiation Research >The influence of physique on dose conversion coefficients for idealised external photon exposures: a comparison of doses for Chinese male phantoms with 10th 50th and 90th percentile anthropometric parameters
【2h】

The influence of physique on dose conversion coefficients for idealised external photon exposures: a comparison of doses for Chinese male phantoms with 10th 50th and 90th percentile anthropometric parameters

机译:体质对理想外部光子照射剂量转换系数的影响:比较具有第十五十和九十个百分位数人体测量学参数的中国男性幻影的剂量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

For evaluating radiation risk, the construction of anthropomorphic computational phantoms with a variety of physiques can help reduce the uncertainty that is due to anatomical variation. In our previous work, three deformable Chinese reference male phantoms with 10th, 50th and 90th percentile body mass indexes and body circumference physiques (DCRM-10, DCRM-50 and DCRM-90) were constructed to represent underweight, normal weight and overweight Chinese adult males, respectively. In the present study, the phantoms were updated by correcting the fat percentage to improve the precision of radiological dosimetry evaluations. The organ dose conversion coefficients for each phantom were calculated and compared for four idealized external photon exposures from 15 keV to 10 MeV, using the Monte Carlo method. The dosimetric results for the three deformable Chinese reference male phantom (DCRM) phantoms indicated that variations in physique can cause as much as a 20% difference in the organ dose conversion coefficients. When the photon energy was <50 keV, the discrepancy was greater. The irradiation geometry and organ position can also affect the difference in radiological dosimetry between individuals with different physiques. Hence, it is difficult to predict the conversion coefficients of the phantoms from the anthropometric parameters alone. Nevertheless, the complex organ conversion coefficients presented in this report will be helpful for evaluating the radiation risk for large groups of people with various physiques.
机译:为了评估辐射风险,具有各种体格的拟人化计算体模的构造可以帮助减少由于解剖变化而引起的不确定性。在我们之前的工作中,构建了三个可变形的中国参考男性幻像,分别具有第10%,50%和90%的体重指数以及体周体质(DCRM-10,DCRM-50和DCRM-90),分别代表体重过轻,体重正常和体重超重的中国成年人男性。在本研究中,通过校正脂肪百分比来更新体模,以提高放射剂量学评估的准确性。计算了每个体模的器官剂量转换系数,并使用蒙特卡洛方法对15 keV至10 MeV的四种理想外部光子曝光进行了比较。三种可变形中国参考男性体模(DCRM)体模的剂量学结果表明,体格变化可导致器官剂量转换系数差异多达20%。当光子能量<50 keV时,差异更大。辐射的几何形状和器官位置也会影响具有不同体质的个体之间的放射剂量学差异。因此,仅从人体测量学参数难以预测体模的转换系数。但是,本报告中介绍的复杂器官转化系数将有助于评估具有各种体质的大量人群的辐射风险。

著录项

相似文献

  • 外文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号