首页> 外文期刊>Radiation Protection Dosimetry >EVALUATION OF IMAGING DOSE FROM DIFFERENT IMAGE GUIDED SYSTEMS DURING HEAD AND NECK RADIOTHERAPY: A PHANTOM STUDY
【24h】

EVALUATION OF IMAGING DOSE FROM DIFFERENT IMAGE GUIDED SYSTEMS DURING HEAD AND NECK RADIOTHERAPY: A PHANTOM STUDY

机译:头部和颈部放射治疗过程中来自不同图像引导系统的成像剂量评估:幻影研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

This work evaluated and compared the absorbed doses to selected organs in the head and neck region from the three image guided radiotherapy systems: cone-beam computed tomography (CBCT) and kilovoltage (kV) planar imaging using the On-board Imager~® (OBI) as well as the ExacTrac~® X-ray system, all available on the Varian Novalis TX linear accelerator. The head and neck region of an anthropomorphic phantom was used to simulate patients' head within the imaging field. Nanodots optically stimulated luminescent dosemeters were positioned at selected sites to measure the absorbed doses. CBCT was found to be delivering the highest dose to internal organs while OBI-2D gave the highest doses to the eye lenses. The setting of half-rotation in CBCT effectively reduces the dose to the eye lenses. Daily high-quality CBCT verification was found to increase the secondary cancer risk by 0.79%.
机译:这项工作评估并比较了三种图像引导放射治疗系统在头颈部区域所选器官的吸收剂量:锥束计算机断层扫描(CBCT)和千伏(kV)平面成像,使用车载成像仪(OBI) )以及ExacTrac〜®X射线系统,均可在Varian Novalis TX线性加速器上使用。拟人化模型的头部和颈部区域用于模拟成像区域内的患者头部。将纳米点光激发的发光剂量计放置在选定的位置以测量吸收的剂量。发现CBCT向内脏器官提供的剂量最高,而OBI-2D向眼眼镜提供的剂量最大。 CBCT中半旋转的设置有效地减少了眼镜片的剂量。发现每日高质量CBCT验证可将继发癌症风险增加0.79%。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2017年第3期|357-362|共6页
  • 作者单位

    Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia and University of Malaya Research Imaging Centre, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia;

    Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia;

    Clinical Oncology Unit, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia;

    Department of Biomedical Imaging, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia and University of Malaya Research Imaging Centre, Faculty of Medicine, University of Malaya, Kuala Lumpur 50603, Malaysia;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号