首页> 外文期刊>Radiation Protection Dosimetry >MEASUREMENT OF RADIATION DOSES TO THE EYE LENS DURING ORTHOPEDIC SURGERY USING AN C-ARM X-RAY SYSTEM
【24h】

MEASUREMENT OF RADIATION DOSES TO THE EYE LENS DURING ORTHOPEDIC SURGERY USING AN C-ARM X-RAY SYSTEM

机译:使用C臂X射线系统在骨科手术期间对眼镜的辐射剂量进行测量

获取原文
获取原文并翻译 | 示例
           

摘要

The present study aimed to determine doses delivered to the eye lenses of surgeons while using the inverted-C-arm technique and the protective effect of leaded spectacles during orthopedic surgery. The kerma in air was measured at five positions on leaded glasses positioned near the eye lens and on the neck using small optically stimulated luminescence (OSL) dosemeters. The lens equivalent dose was also measured at the neck using an OSL dosemeter. The maximum equivalent dose to the eye lens and the maximum kerma were 0.8 mSv/month and 0.66 mGy/month, respectively. The leaded glasses reduced the exposure by similar to 60%. Even if the surgeons are exposed to the maximum dose of X-ray radiation for 5 years, the equivalent doses to the eye lens will not exceed the present limit recommended by the ICRP.
机译:本研究旨在确定在使用倒C型臂技术时向外科医生的眼镜片输送的剂量以及整形外科手术中铅眼镜的保护作用。使用小型的光激发发光(OSL)剂量计,在靠近眼镜片和脖子的有铅玻璃上的五个位置测量空气中的比释动能。还使用OSL剂量计在颈部测量镜片当量剂量。眼晶状体的最大当量剂量和最大动骨比分别为0.8 mSv /月和0.66 mGy /月。含铅玻璃使暴露减少了约60%。即使外科医生在X射线的最大剂量下暴露了5年,眼镜的等效剂量也不会超过ICRP建议的当前限值。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2018年第2期|189-195|共7页
  • 作者单位

    Japanese Red Cross Sendai Hosp, Dept Radiol, 2-43-3 Yagiyama Honcho, Sendai, Miyagi 9828501, Japan;

    Kanazawa Univ, Dept Quantum Med Technol, Fac Hlth Sci, 5-11-80 Kodatsuno, Kanazawa, Ishikawa 9200942, Japan;

    Japanese Red Cross Sendai Hosp, Dept Radiol, 2-43-3 Yagiyama Honcho, Sendai, Miyagi 9828501, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);