As the structural health monitoring tools,three subapace-based system identification methods,the ordinary MOESP,the N4SID and the PO-MOESP, were investigated to discuss the identification accuracy of natural frequency and damping factor of buildings. Fundamental case studies using SDOF response data revealed that the identification accuracy of the N4SID was lower than those of the ordinary MOESP and the PO-MOESP. This was because the 2-norm of the matrix applied to the noise in the N4SID was larger than the other methods. Finally, the difference in identification accuracy between three methods was verified by using the strong motion records of an RC super high-rise residential building during the 2011 off the Pacific coast oflbhoku Earthquake.%昨今,建物の既存ストックの有効活用ゃ地震後の耐震安全性を検討する観点から,構造へルスモニタリングが注目されている。これは建物に作用する入力(地震動等)と出力(建物応答)の観測データを用いたシステム同定理論に基づくものである。地震時の構造へルスモニタリングに用いるシステム同定手法としてARXモデルがあるが,この手法では基本的に1入力1出力(Single Input Single Output, SISO)システムを対象としており,拡張された手法はあるものの,多入力多出力(Multi Input Multi Output, MIMO)システムは対象外である場合が多い。
机译:作为结构健康监测工具,研究了基于子空间的三种系统识别方法,即普通的MOESP,N4SID和PO-MOESP,以探讨建筑物固有频率和阻尼因子的识别准确性。揭示了N4SID的识别精度低于普通M​​OESP和PO-MOESP,这是因为应用于N4SID的噪声的矩阵的2范数大于其他方法。通过使用2011年lbhoku地震太平洋沿岸一栋RC超高层住宅建筑物的强运动记录,验证了三种方法之间的识别准确性。%最近,有效利用现有建筑物和地震后的地震安全性从研究结构健康监测的观点出发,已经对结构健康监测给予了关注。这是基于系统识别理论的,它使用作用在建筑物上的输入(地震运动)和输出(建筑物响应)的观测数据。有一种ARX模型作为用于地震期间结构健康监测的系统识别方法,但是该方法主要针对单输入单输出(SISO)系统,并且存在扩展方法。在许多情况下,它不适用于多输入多输出(MIMO)系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号