Investigations of a number of generator stator-insulation failures have shown that breakdowns of several machines generating at 33 kV were initiated by discharge erosion of the insulation. The paper describes a method of measuring discharges in stator insulation. The technique consists in counting the number of discharge pulses exceeding a certain level. It is concluded that this proposed instrument has several advantages over other types of discharge detector. It is shown that, at the present time, this method, or indeed any other means of measuring discharges, cannot determine the depth of discharge erosion in generator stator insulation. In a complete stator winding, the internal discharges tend to be concealed by slot discharges, which may or may not be harmful, depending on the surface conductivity of the dielectric.
机译:对许多发电机定子绝缘故障的研究表明,以33 kV发电的几台电机的故障是由绝缘材料的放电腐蚀引起的。本文介绍了一种测量定子绝缘中放电的方法。该技术在于对超过一定水平的放电脉冲数进行计数。结论是,与其他类型的放电检测器相比,该提议的仪器具有多个优点。结果表明,目前,这种方法,或者实际上是任何其他测量放电的方法,都无法确定发电机定子绝缘中的放电腐蚀深度。在完整的定子绕组中,内部放电往往被槽孔放电掩盖,根据电介质的表面电导率,槽孔放电可能有害也可能无害。