The Stator winding insulation is aged by exposure to a combination of thermal, electrical, mechanical, and environmental stresses. Diagnosis of stator winding insulation is an important measure of ensuring the safe operation and extending the remaining life of large generator. In the paper, two new parameters are proposed for the diagnosis of stator winding insulation based on the test results of multistress accelerating aging test of stator bars. The test results show that the skewness of partial discharge phase resolved distribution and the high-frequency crest of partial discharge (PD) impulse change much more remarkably with the aging time than do the conventional parameters. Therefore, the two parameters could be considered as characteristic parameters for the diagnosis of stator winding insulation of the large generator. With these characteristic parameters, authors successfully assessed the insulation condition of actual stator bars removed from several large generators.
机译:定子绕组的绝缘层会受到热,电,机械和环境应力的共同作用而老化。定子绕组绝缘的诊断是确保安全运行并延长大型发电机剩余寿命的重要措施。本文基于定子线棒多应力加速老化试验的测试结果,提出了两个新的定子绕组绝缘诊断参数。测试结果表明,随着时间的流逝,局部放电相位分辨分布的偏度和局部放电的高频波峰随老化时间的变化比常规参数要明显得多。因此,可以将这两个参数视为诊断大型发电机定子绕组绝缘的特征参数。利用这些特征参数,作者成功地评估了从几台大型发电机上卸下的实际定子棒的绝缘状态。