In light-duty contacts failure is caused less frequently by erosion than by high resistance due to contamination of the surface. The best guide to the degree of contamination of a contact is obtained by measuring its resistance in such a way as to avoid damaging the surface film, even if the normal use of the contact may entail such damage. A 4-terminal method of measurement should be used in order separate the resistance of the contact from that of the switching device as a whole and its connections to the measuring network. The conditions in which the separation is physically meaningful are considered, and a simple calculation indicates where the connections should made in a typical case. Theoretical arguments, supported by experiment, are given for limiting the test voltage to 10mV. The current need not be limited provided that the circuit is de-energized during make and break prevent damage to surface films by inductive voltage peaks. If this not done the current must be limited to a very small value, with serious loss in sensitivity.
机译:在轻型接触器中,由腐蚀引起的故障发生的频率要比由表面污染引起的高电阻引起的故障发生的频率低。即使接触器的正常使用可能会造成这种损坏,也可以通过避免接触器损坏表面膜的方式来测量其电阻,从而获得接触器污染程度的最佳指南。为了将触点的电阻与整个开关设备的电阻及其与测量网络的连接分开,应使用4端子测量方法。考虑到分离在物理上有意义的条件,简单的计算表明在典型情况下应在何处进行连接。给出了实验支持的理论论据,以将测试电压限制为10mV。电流不受限制,只要在接通和断开期间电路断电以防止感应电压峰值损坏表面膜即可。如果不这样做,则必须将电流限制在很小的范围内,从而导致灵敏度严重下降。