首页> 外文期刊>Power technology and engineering >ANALYSIS OF THE TRIP OF A HIGH-POWER TURBINE-GENERATOR OF A NUCLEAR POWER PLANT UPON DAMAGE OF THE STATOR WINDING INSULATION ACCORDING TO DATA OF MONITORING AND MODELING
【24h】

ANALYSIS OF THE TRIP OF A HIGH-POWER TURBINE-GENERATOR OF A NUCLEAR POWER PLANT UPON DAMAGE OF THE STATOR WINDING INSULATION ACCORDING TO DATA OF MONITORING AND MODELING

机译:根据监测与建模数据,分析核电厂一台大功率汽轮发电机定子绕组绝缘损坏的跳闸现象

获取原文
获取原文并翻译 | 示例
       

摘要

The operating conditions of a turbine-generator with the stator winding short-circuited to the frame are analyzed. The features of the shape of the zero-sequence voltage during arcing in the damaged gap are described. The operation of the relay protection in these conditions is analyzed. The real oscillograms of the subsequent suppression of the rotor field are theoretically justified. It is shown that improving the thyristor excitation system is necessary and possible.
机译:分析了定子绕组与框架短路的水轮发电机的工作条件。描述了在电弧放电期间在损坏的间隙中零序电压的形状特征。分析了在这些条件下的继电保护功能。从理论上讲,随后抑制转子磁场的实际波形图是合理的。结果表明,改进晶闸管励磁系统是必要和可能的。