The IEC Standard 60287-1-1 contains the formulae for the calculation of the sheath and armor loss factors of a 3-phase cable system. Sheath circulating current losses are computed for single-, multiple-, or cross-bonded systems. This paper deals with cross-bonded cable systems. For unequal minor section lengths, the standard gives a formula allowing calculation of the circulating current losses when the lengths of the minor sections are known. The origin of this formula is not documented; hence, this paper gives its derivation. When the lengths of the minor sections are not known, the standard suggests using a factor of 0.004, which multiplies the circulating current loss factor computed for a multi-point bonded system. In this paper, the cable sheath circulating loss factor was found using different methods with the aim of checking the applicability of the 0.004 multiplier to practical cable systems with differences in the length of minor sections and system voltage. Three different cable systems are studied; the first is a 132 kV circuit with known lengths of minor and major sections. The second circuit is a 220 kV system where the lengths of minor sections are unknown and the third is a 220 kV real system with known, highly irregular section lengths. The calculated values of sheath circulating current loss factor, applying the formulas from the IEC 60287-1-1, were compared to the values calculated based on practical measurements of sheath induced voltages and currents. The effect of taking the measured and IEC values on the continuous current rating (ampacity) is also presented for the first two circuits and the comparison of the unknown and known section lengths for the third circuit is offered.
机译:IEC标准60287-1-1包含用于计算3相电缆系统的护套和装甲损耗因子的公式。为单,多个或交叉键合系统计算鞘循环电流损耗。本文涉及交叉键合电缆系统。对于不平等的次要截面长度,该标准给出了允许在已知次要部分的长度时计算循环电流损耗的公式。该公式的起源未记录;因此,本文给出了它的推导。当未知次要部分的长度不知道时,标准建议使用0.004的因子,该因子乘以为多点粘合系统计算的循环电流损耗因子。在本文中,使用不同方法发现电缆护套循环损耗因子,目的是检查0.004乘法器对实用电缆系统的适用性,具有较小部分和系统电压的长度的差异。研究了三种不同的电缆系统;首先是132 kV电路,具有已知长度的次要和主要部分。第二电路是220kV系统,其中次要部分的长度未知,第三电路是具有已知的高度不规则的截面长度的220kV真实系统。将从IEC 60287-1-1应用公式的鞘循环电流损耗因子的计算值与基于护套的实际测量计算的值进行比较。对于前两个电路还呈现了对连续电流额定值(余量)进行测量和IEC值的效果,并且提供了第三电路的未知和已知部分长度的比较。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号