首页> 外文期刊>Polymer Degradation and Stability >Rheological characterization of a thermally unstable bioplastic in injection molding conditions
【24h】

Rheological characterization of a thermally unstable bioplastic in injection molding conditions

机译:注射成型条件下热不稳定生物塑料的流变特性

获取原文
获取原文并翻译 | 示例
           

摘要

Poly(hydroxy-alcanoates) bioplastics have an unusually small temperature processing window due to their thermal instability, which affects both molecular weight distribution and rheological behavior. The use of a rheometrical device mounted on an injection molding machine has been shown to allow the study of dynamic viscosity variations for very short residence times in the melt (down to a few tens of seconds). Moreover, dynamic viscosity can be obtained over a wide range of shear rates (up to 50000 s~(-1)) with both Bagley and Rabinowitsch corrections. The rheological data obtained for a poly(3-hydroxybutyrate-co-3-hydroxyvalerate), PHBV copolymer shows that the reduction in viscosity associated with degradation is very fast and is detectable even at temperatures close to the melting point. Size Exclusion Chromatography analysis of selected samples shows that, except for residence times below 15s, molecular mass distribution is substantially affected, shifting toward lower masses, and with an increase in oligomer compound content. These oligomers may act as plasticizers of the bioplastic. The results also suggest that important thermomechanical degradation takes place during the plas-ticization/feeding step of injection molding.
机译:聚(羟基-铝酸酯)生物塑料由于其热不稳定性而具有异常小的温度处理窗口,这会影响分子量分布和流变行为。业已表明,使用安装在注塑机上的流变仪可以研究熔体中非常短的停留时间(低至数十秒)的动态粘度变化。而且,通过巴格利和拉比诺维奇校正,可以在很宽的剪切速率范围内(高达50000 s〜(-1))获得动态粘度。聚(3-羟基丁酸酯-co-3-羟基戊酸酯)PHBV共聚物获得的流变数据表明,与降解相关的粘度降低非常快,即使在接近熔点的温度下也可以检测到。所选样品的尺寸排阻色谱分析表明,除停留时间低于15秒外,分子质量分布受到显着影响,向较低质量方向移动,并且低聚物化合物含量增加。这些低聚物可以充当生物塑料的增塑剂。结果还表明,重要的热机械降解发生在注塑成型的塑化/进料步骤中。

著录项

  • 来源
    《Polymer Degradation and Stability》 |2012年第10期|p.1915-1921|共7页
  • 作者单位

    WNAM Universite, CNRS, CEPEA, UMR 6144. CRTT, 37, Avenue de l'Universite, 44606 St Nazaire Cedex, France;

    LUNAM Universite. IUT de Nantes, CNRS, CEPEA, UMR 6744, OPERP ERT1086. 2, Avenue du Professeur Jean Rouxel, BP 539. 44475 Carquefou Cedex, France;

    Laboratoire Chimie et Ingenierie des Procides (C1P), Sciences Chimiques de Rennes (UMR CNRS 6226), Universiti de Rennes I/ENSCR, Avenue du General Leclerc, 35700 Rennes, France;

    LUNAM Universite. IUT de Nantes, CNRS, CEPEA, UMR 6744, OPERP ERT1086. 2, Avenue du Professeur Jean Rouxel, BP 539. 44475 Carquefou Cedex, France;

    LUNAM Universite. IUT de Nantes, CNRS, CEPEA, UMR 6744, OPERP ERT1086. 2, Avenue du Professeur Jean Rouxel, BP 539. 44475 Carquefou Cedex, France;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    poly( hydroxy-alkanoates); bioplastics; rheology; thermal degradation; injection molding; inline monitoring;

    机译:聚(羟基链烷酸酯);生物塑料流变学热降解;注塑成型在线监控;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号