This work focuses on the accuracy of the mode content measurements in an overmoded corrugated waveguide using measured radiated field patterns. Experimental results were obtained at 250 GHz using a vector network analyzer with over 70 dB of dynamic range. The intensity and phase profiles of the fields radiated from the end of the 19 mm diameter helically tapped brass waveguide were measured on planes at 7, 10, and 13 cm from the waveguide end. The measured fields were back propagated to the waveguide aperture to provide three independent estimates of the field at the waveguide exit aperture. Projecting that field onto the modes of the guide determined the waveguide mode content. The three independent mode content estimates were found to agree with one another to an accuracy of better than $pm$0.3%. These direct determinations of the mode content were compared with indirect measurements using the experimentally measured amplitude in three planes, with the phase determined by a phase retrieval algorithm. The phase retrieval technique using the planes at 7, 10, and 13 cm yielded a mode content estimate in excellent agreement, within 0.3%, of the direct measurements. Phase retrieval results using planes at 10, 20, and 30 cm were less accurate due to truncation of the measurement in the transverse plane. The reported measurements benefited greatly from a precise mechanical alignment of the scanner with respect to the waveguide axis. These results will help to understand the accuracy of mode content measurements made directly in cold test and indirectly in hot test using the phase retrieval technique.
机译:这项工作着重于使用测量的辐射场模式在过调制波纹波导中模式含量测量的准确性。使用矢量网络分析仪在250 GHz上获得了超过70 dB的动态范围的实验结果。在距波导端7、10和13 cm的平面上测量了从直径为19 mm的螺旋锥状黄铜波导的端部辐射出的场的强度和相位分布。测得的场被反向传播到波导孔,以提供在波导出口孔处的场的三个独立估计。将该场投影到波导的模式上可以确定波导模式的内容。发现这三个独立模式的内容估计彼此之间的准确性高于$ pm $ 0.3%。将这些对模式内容的直接确定与使用在三个平面中通过实验测量的振幅,通过相位检索算法确定相位的间接测量进行比较。使用7、10和13 cm平面的相位检索技术得出的模态含量估算值与直接测量值相差0.3%以内。由于在横向平面上测量的截断,使用10、20和30 cm平面的相位恢复结果的准确性较差。所报告的测量结果极大地受益于扫描仪相对于波导轴的精确机械对准。这些结果将有助于了解使用相位检索技术直接在冷测试中和间接在热测试中进行的模式内容测量的准确性。

著录项

  • 来源
    《Plasma Science, IEEE Transactions on》 |2012年第6期|p.1530-1537|共8页
  • 作者

    Jawla S. K.;

  • 作者单位
  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号