首页> 外文期刊>Planetary and space science >The effect of spacecraft radiation sources on electron moments from the Cassini CAPS electron spectrometer
【24h】

The effect of spacecraft radiation sources on electron moments from the Cassini CAPS electron spectrometer

机译:航天器辐射源对卡西尼CAPS电子光谱仪电子矩的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Data from the Cassini plasma spectrometer (CAPS) electron spectrometer (ELS) have been found to be contaminated with an energy-independent background count rate which has been associated with radiation sources on Cassini. In this paper we describe this background radiation and quantitatively assess its impact on numerically integrated electron moments. The general properties of such a background and its effects on numerical moments are derived. The properties of the ELS background are described and a model for the background presented. A model to generate synthetic ELS spectra is presented and used to evaluate the density and temperature of pure noise and then extended to include ambient distributions. It is shown that the presence of noise produces a saturation of the electron density and temperature at quasi-constant values when the instrument is at background, but that these noise level moments are dependent on the floating spacecraft potential and the orientation of the ELS instrument with respect to the spacecraft. When the ambient distribution has a poor signal-to-noise ratio (SNR) the noise determines the density and temperature; however, as the SNR increases (increasing primarily with density) the density and temperature tend to those of the ambient distribution. It is also shown that these noise effects produce highly artificial density-temperature inverse correlations. A method to subtract this noise is presented and shown to correct for the presence of the noise. Simulated error estimates for the density and temperature are also presented. The analysis described in this paper not only applies to weak background noise, but also to more significant penetrating backgrounds such as those in radiation belt regions of planetary magnetospheres.
机译:已发现来自卡西尼等离子体光谱仪(CAPS)电子光谱仪(ELS)的数据受到与能量无关的本底计数率的污染,该计数率与卡西尼号上的辐射源有关。在本文中,我们描述了这种背景辐射,并定量评估了其对数值积分电子矩的影响。推导了这种背景的一般特性及其对数值矩的影响。描述了ELS背景的属性,并提供了背景模型。提出了用于生成合成ELS光谱的模型,该模型用于评估纯噪声的密度和温度,然后扩展为包括环境分布。结果表明,当仪器处于背景时,噪声的存在会在准常数值处产生电子密度和温度的饱和,但是这些噪声级矩取决于浮动航天器的电势和ELS仪器的方向。尊重航天器。当环境分布的信噪比(SNR)较差时,噪声将决定密度和温度。但是,随着SNR的增加(主要随密度增加),密度和温度趋向于环境分布的密度和温度。还显示出这些噪声效应产生高度人为的密度-温度反相关。提出并示出了一种减去该噪声的方法以校正噪声的存在。还介绍了密度和温度的模拟误差估计。本文描述的分析不仅适用于弱背景噪声,而且适用于更重要的穿透背景,例如行星磁层辐射带区域中的背景。

著录项

  • 来源
    《Planetary and space science》 |2009年第7期|854-869|共16页
  • 作者单位

    Mullard Space Science Laboratory, Department of Space and Climate Physics, University College London, Holmbury St. Mary, Dorking, Surrey, RH5 6NT, UK The Centre for Planetary Sciences at UCL/Birkbeck, University College London, Cower St., London, WC1E 6BT, UK;

    Mullard Space Science Laboratory, Department of Space and Climate Physics, University College London, Holmbury St. Mary, Dorking, Surrey, RH5 6NT, UK The Centre for Planetary Sciences at UCL/Birkbeck, University College London, Cower St., London, WC1E 6BT, UK;

    Mullard Space Science Laboratory, Department of Space and Climate Physics, University College London, Holmbury St. Mary, Dorking, Surrey, RH5 6NT, UK The Centre for Planetary Sciences at UCL/Birkbeck, University College London, Cower St., London, WC1E 6BT, UK;

    NASA Goddard Space Flight Centre, Greenbelt, MD, USA;

    Mullard Space Science Laboratory, Department of Space and Climate Physics, University College London, Holmbury St. Mary, Dorking, Surrey, RH5 6NT, UK The Centre for Planetary Sciences at UCL/Birkbeck, University College London, Cower St., London, WC1E 6BT, UK;

    Mullard Space Science Laboratory, Department of Space and Climate Physics, University College London, Holmbury St. Mary, Dorking, Surrey, RH5 6NT, UK;

    Mullard Space Science Laboratory, Department of Space and Climate Physics, University College London, Holmbury St. Mary, Dorking, Surrey, RH5 6NT, UK The Centre for Planetary Sciences at UCL/Birkbeck, University College London, Cower St., London, WC1E 6BT, UK;

    Southwest Research Institute, San Antonio, TX, USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    cassini; electrostatic analyser; penetrating radiation; moments; noise subtraction;

    机译:卡西尼静电分析仪穿透辐射时刻噪声减法;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号