首页> 外文期刊>Pipeline & gas journal >Orifice and Ultrasonic Meters in Wet Gas Flow Service
【24h】

Orifice and Ultrasonic Meters in Wet Gas Flow Service

机译:湿气流服务中的孔板和超声波仪表

获取原文
获取原文并翻译 | 示例
           

摘要

Wet gas flow has adverse effects on all gas meters. Both orifice meters and USM have degraded performance in wet gas applications. Wet gas causes the orifice meter to significantly over-read the gas flow. However, this over-reading is predictable and for a known liquid flow rate an ISO-published correction factor can correct the gas flow rate prediction to 2% at 95% confidence. Furthermore, an orifice meter liquid monitoring system is available that can specifically identify wet gas flow by XLM ≥ 0.01. Wet gas causes the ultrasonic meter to significantly over-read the gas flow. To date, no ultrasonic meter correction factor has been published. However, the USM diagnostic system is capable of identifying a generic problem exists by a wetness of XLM ≥ 0.01.
机译:湿气流对所有燃气表都有不利影响。孔板流量计和USM在湿气应用中的性能均下降。湿气会导致节流孔计明显过量读取气流。但是,这种过度读取是可以预测的,对于已知的液体流速,ISO发布的校正因子可以在95%置信度下将气体流速预测值校正为2%。此外,还可以使用孔板流量计液体监控系统,该系统可以通过XLM≥0.01专门识别湿气流。湿气会导致超声波仪表明显过度读取气流。迄今为止,尚未发布超声仪校正因子。但是,USM诊断系统能够通过XLM≥0.01的湿度来识别存在的一般问题。

著录项

  • 来源
    《Pipeline & gas journal》 |2015年第9期|64-65|共2页
  • 作者

    Richard Steven; Josh Kinney;

  • 作者单位
  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号