The superconducting isochronous cyclotron SC200 for proton therapy is under development in Hefei, and the active scanning method has been selected as the beam delivery technology. To reduce energy loss and transverse scattering of the proton beam, a gas chamber in the pencil beam scanning (PBS) nozzle has been designed to shorten the length of the air segment. To determine whether using a helium filling gas or vacuum is the most suitable for the SC200 PBS nozzle, the beam size and the energy loss at the isocenter and the dose distribution in the water phantom are compared using the TOol for PArticle Simulation (TOPAS) code. The results show that using the helium filling gas resulted in scattering and energy loss of the proton beam compared with using vacuum, but these effects were minimal. Considering the disadvantages of the engineering problems of creating a vacuum chamber, helium was selected as the filling gas for the PBS nozzle chamber. Moreover, the following parameters were analyzed and optimized: gas pressure, gas purity, and film thickness of the chamber. When the helium pressure was below 1.1 atm and the air proportion was less than 5%, the beam size at the lowest energy of the proton beam at the isocenter was lower than 8 mm, meeting the clinical requirements.
机译:用于质子治疗的超导同步回旋加速器SC200正在合肥开发,并且主动扫描方法已被选作束传输技术。为了减少能量损失和质子束的横向散射,笔形束扫描(PBS)喷嘴中的气室已设计成可缩短空气段的长度。为了确定使用氦气填充气体还是真空气体最适合SC200 PBS喷嘴,使用TOART for PArticle Simulation(TOPAS)代码比较了束大小,等中心处的能量损失以及水模中的剂量分布。结果表明,与使用真空相比,使用氦气填充气体会导致质子束的散射和能量损失,但这些影响很小。考虑到创建真空室的工程问题的弊端,选择氦气作为PBS喷嘴室的填充气体。此外,分析并优化了以下参数:气压,气体纯度和腔室的膜厚。当氦气压力低于1.1个大气压且空气比例小于5%时,等中心质子束最低能量的束尺寸小于8 mm,符合临床要求。

著录项

  • 来源
    《Nuclear Technology》 |2020年第5期|779-790|共12页
  • 作者

  • 作者单位

    Institute of Plasma Physics Chinese Academy of Sciences Hefei Anhui China University of Science and Technology of China Hefei Anhui China;

    Institute of Plasma Physics Chinese Academy of Sciences Hefei Anhui China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    SC200; PBS nozzle; gas chamber; proton beam; TOPAS;

    机译:SC200;PBS喷嘴;毒气室;质子束托帕斯;
  • 入库时间 2022-08-18 05:18:55

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号