首页> 外文期刊>Nuclear Instruments & Methods in Physics Research. B, Beam Interactions with Materials and Atoms >Ionoluminescence analysis of glass scintillators and application to single-ion-hit real-time detection
【24h】

Ionoluminescence analysis of glass scintillators and application to single-ion-hit real-time detection

机译:玻璃闪烁体的电致发光分析及其在单离子碰撞实时检测中的应用

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

In this paper, we propose and test a real-time detection system for single-ion hits using mega-electronvolt (MeV)-heavy ions. The system was constructed using G2000 and G9 glass scintillators, as well as an electron-multiplying charge-coupled device (EMCCD) camera combined with an inverted microscope with a lOx objective lens. Commercially available G2000 and G9 glass scintillators, which have been reported to exhibit strong photoluminescence at 489, 543, 585, and 622 nm as a result of the Tb~(3+) f-f transition, were employed for highly accurate ionized particle detection. The EMCCD camera had a resolution of 512 × 512 pixels, each with a size of 16 nm × 16 μm, and a maximum linear gain of 8 × 10~5 electrons. For 260-MeV Ne, 3 ion hits/s were detected by our system. The intensity of the ionoluminescence (IL) peak induced by the heavy ions was 140 times the noise intensity. In contrast the luminous diameter at the full width at half maximum (FWHM) in both the horizontal and vertical directions was calculated to be approximately 4.5 μm. These results suggest that our detection system can accurately detect single-ion hits with a diameter of the order of 1 μm.
机译:在本文中,我们提出并测试了使用兆电子伏(MeV)重离子的单离子命中的实时检测系统。该系统使用G2000和G9玻璃闪烁体以及带倍增物镜的倒置显微镜结合的电子倍增电荷耦合器件(EMCCD)相机构成。据报道,由于Tb〜(3+)f-f跃迁的结果,市售的G2000和G9玻璃闪烁体在489、543、585和622 nm处显示出强大的光致发光,可用于高精度电离粒子检测。 EMCCD相机的分辨率为512×512像素,每个像素的尺寸为16 nm×16μm,最大线性增益为8×10〜5个电子。对于260 MeV Ne,我们的系统检测到3个离子命中/秒。重离子诱导的电致发光(IL)峰的强度是噪声强度的140倍。相反,在水平和垂直方向上的半峰全宽(FWHM)处的发光直径被计算为大约4.5μm。这些结果表明,我们的检测系统可以准确检测直径为1μm的单离子命中。

著录项

  • 来源
  • 作者单位

    Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan , Takasaki Advanced Radiation Research Institute (TARRI), Japan Atomic Energy Agency (JAEA), 1233 Watanuki-machi, Takasaki, Gunma 370-1292, Japan;

    Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan;

    Takasaki Advanced Radiation Research Institute (TARRI), Japan Atomic Energy Agency (JAEA), 1233 Watanuki-machi, Takasaki, Gunma 370-1292, Japan;

    Takasaki Advanced Radiation Research Institute (TARRI), Japan Atomic Energy Agency (JAEA), 1233 Watanuki-machi, Takasaki, Gunma 370-1292, Japan;

    Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan;

    Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan;

    Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan;

    Graduate School of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515, Japan;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Single-ion hit (SIH); Real-time detection; Ionoluminescence (IL); G2000;

    机译:单离子击中(SIH);实时检测;离子发光(IL);G2000;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号