We present Monte-Carlo simulations for the focusing design of a novel cold-neutron triple-axis spectrometer to be installed at the end position of the cold guide NL-1 of the research reactor FRM-II in Munich, Germany. Our simulations are of general relevance for the design of triple-axis spectrometers at end positions of neutron guides. Using the McStas program code we performed ray trajectories to compare parabolic and elliptic focusing concepts. In addition the design of the monochromator was optimized concerning crystal size and mosaic spread. The parabolic focusing concept is superior to the elliptic alternative in view of the neutron intensity distribution as a function of energy and divergence. In particular, the elliptical configuration leads to an inhomogeneous divergence distribution.
机译:我们提供了蒙特卡洛模拟,用于新型冷中子三轴光谱仪的聚焦设计,该光谱仪将安装在德国慕尼黑研究堆FRM-II的冷导管NL-1的末端。我们的模拟与中子导管末端位置的三轴光谱仪的设计具有普遍意义。使用McStas程序代码,我们执行了射线轨迹以比较抛物线形和椭圆形聚焦概念。另外,单色器的设计在晶体尺寸和镶嵌扩散方面进行了优化。考虑到中子强度分布是能量和发散的函数,抛物线聚焦概念优于椭圆形替代。特别地,椭圆形构造导致不均匀的发散分布。