The Forward Time-of-Flight system for the large-acceptance CLAS12 spectrometer in Hall B at the Thomas Jefferson National Accelerator Facility is described. The system is positioned at distances in the range from 6.2 m to 7,2 m from the beam-target interaction point and spans laboratory polar angles from 5°→45° and nearly the full azimuth. The system consists of 540 individual scintillation counters with double-ended readout that range in length from 17 cm to 426 cm of discrete widths of 6 cm, 15 cm, and 22 cm, and of discrete thicknesses of 5 cm and 6 cm. The effective counter time resolution for passing charged particles varies from 50 ps for the shortest counters at small angles to 200 ps for the longest counters at large angles. The detectors are part of the forward-angle particle identification system for CLAS12 during offline event reconstruction and are a component of the online data acquisition trigger to select final state event topologies with forward-going charged particles.
机译:描述了托马斯·杰斐逊国家加速器设施B厅中大接收CLAS12光谱仪的正向飞行时间系统。该系统距光束与目标的相互作用点的距离在6.2 m至7.2 m之间,并且跨越了5°→45°的实验室极角,并接近整个方位角。该系统由540个具有双端读数的独立闪烁计数器组成,其读数范围从17厘米到426厘米,离散宽度分别为6厘米,15厘米和22厘米,离散厚度为5厘米和6厘米。通过带电粒子的有效计数器时间分辨率从小角度的最短计数器的50 ps到大角度的最长计数器的200 ps不等。这些检测器是离线事件重建期间CLAS12的前角粒子识别系统的一部分,并且是在线数据采集触发器的组成部分,用于选择带有前向带电粒子的最终状态事件拓扑。