首页> 外文期刊>Nuclear Engineering and Design >Reanalysis and evaluation of the seismic capacity of the CANDU 700 MW NPP CERNAVODA
【24h】

Reanalysis and evaluation of the seismic capacity of the CANDU 700 MW NPP CERNAVODA

机译:重新分析和评估CANDU 700 MW NPP CERNAVODA的抗震能力

获取原文
获取原文并翻译 | 示例
       

摘要

The dynamic response of structures of the CANDU 700 MW NPP due to seismic loadings was conventionally analyzed in the time domain using modal substructure procedures. The frequency-independent parameters were tuned to the main frequencies of the soil-structure system. this is a common procedure widely used in the preliminary design of power plant structures and provides conservative results. However, parallel to the rapid progress being made in upgrading the capability of data processing systems, methods and software tools have become available which work in the frequency domain using complex (soil-structure) mathematical models or models in which the soil is represented by frequency-dependent impedances.
机译:传统上,在时域中使用模态子结构程序分析了CANDU 700 MW NPP结构由于地震荷载引起的动力响应。与频率无关的参数已调整到土壤结构系统的主要频率。这是在发电厂结构的初步设计中广泛使用的通用程序,可提供保守的结果。但是,与在升级数据处理系统的能力方面取得快速进展的同时,已经出现了在频域中使用复杂的(土壤结构)数学模型或以频率表示土壤的模型的方法和软件工具。依赖的阻抗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com