首页> 外文期刊>Nature >Detection of magnetic circular dichroism using a transmission electron microscope
【24h】

Detection of magnetic circular dichroism using a transmission electron microscope

机译:使用透射电子显微镜检测圆形圆二色性

获取原文
获取原文并翻译 | 示例
       

摘要

A material is said to exhibit dichroism if its photon absorption spectrum depends on the polarization of the incident radiation. In the case of X-ray magnetic circular dichroism (XMCD), the absorption cross-section of a ferromagnet or a paramagnet in a magnetic field changes when the helicity of a circularly polarized photon is reversed relative to the magnetization direction. Although similarities between X-ray absorption and electron energy-loss spectroscopy in a transmission electron microscope (TEM) have long been recognized, it has been assumed that extending such equivalence to circular dichroism would require the electron beam in the TEM to be spin-polarized. Recently, it was argued on theoretical grounds that this assumption is probably wrong(1). Here we report the direct experimental detection of magnetic circular dichroism in a TEM. We compare our measurements of electron energy-loss magnetic chiral dichroism (EMCD) with XMCD spectra obtained from the same specimen that, together with theoretical calculations, show that chiral atomic transitions in a specimen are accessible with inelastic electron scattering under particular scattering conditions. This finding could have important consequences for the study of magnetism on the nanometre and subnanometre scales, as EMCD offers the potential for such spatial resolution down to the nanometre scale while providing depth information-in contrast to X-ray methods, which are mainly surface-sensitive.
机译:如果材料的光子吸收光谱取决于入射辐射的偏振,则该材料将显示出二向色性。在X射线磁性圆二色性(XMCD)的情况下,当圆偏振光子的螺旋度相对于磁化方向反转时,磁场中的铁磁体或顺磁体的吸收截面发生变化。尽管人们早已认识到透射电子显微镜(TEM)中X射线吸收和电子能量损失谱之间的相似性,但已假定将这种等效性扩展到圆二色性会要求TEM中的电子束自旋极化。最近,有人从理论上论证了这一假设可能是错误的(1)。在这里,我们报告了在TEM中直接检测磁性圆二色性的实验。我们将我们的电子能量损失磁性手性二色性(EMCD)与从同一样品获得的XMCD光谱的测量结果进行了比较,再加上理论计算,结果表明,在特定散射条件下,非弹性电子散射可接近样品中的手性原子跃迁。这一发现可能会对纳米和亚纳米尺度的磁性研究产生重要影响,因为EMCD可以提供低至纳米尺度的空间分辨率,同时提供深度信息,这与X射线方法相反,后者主要是表面辐射。敏感。

著录项

  • 来源
    《Nature》 |2006年第7092期|p. 486-488|共3页
  • 作者单位

    Vienna Tech Univ, Serv Ctr Transmiss Electron Microscopy, A-1040 Vienna, Austria;

    Vienna Tech Univ, Inst Festkorperphys, A-1040 Vienna, Austria;

    Inst Phys ASCR, Prague 16253 6, Czech Republic;

    CNR Natl Lab, TASC INFM, I-34012 Trieste, Italy;

    Univ Trieste, I-34100 Trieste, Italy;

    Univ Modena & Reggio, Dipartimento Fis, I-41100 Modena, Italy;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 自然科学总论;
  • 关键词

    X-RAY-DICHROISM; SPECTROSCOPY; ORIGIN; IRON; CO;

    机译:X射线二色性;光谱学;原点;铁;CO;
  • 入库时间 2022-08-18 02:56:29