首页> 外文期刊>Nanoscience and nanotechnology research in Catalonia >Estimation of aquifer recharge by means of atmospheric chloride deposition balance in the soil
【24h】

Estimation of aquifer recharge by means of atmospheric chloride deposition balance in the soil

机译:利用土壤中大气氯化物沉积平衡估算含水层补给量

获取原文
获取原文并翻译 | 示例
       

摘要

En estat estacionari, la deposició de clorur atmosfèric sobre el terreny permet estimar la recàrrega mitjana en els aqüí-fers a llarg termini quan el contingut mitjà de clorurs de l'aigua de recàrrega és conegut. És un mètode senzill, ben conegut, però no sense dificultats teòriques I pràctiques, malgrat que el seu potencial, sovint, no s'aplica. En circumstàncies favorables els resultats obtinguts són fiables I permeten estimar-ne la incertesa. El contingut en clorurs de la recàrrega es pot deduir del mostreig de la part superior del nivell freàtic. El mètode I la seva millora han estat l'objectiu de recerca I d'aplicació en diversos aqüífers I en tot el territori espanyol, com a part de projectes de recerca aplicada I de tesis doctorals lligades al Grup d'Hidrologia Subterrània del Departament d'Enginyeria del Terreny, Cartogràfica I Geofísica, de la Universitat Politècnica de Catalunya (UPC). En el cas d'aqüífers que descarreguen en brolladors o són explotats mitjançant pous profunds, la mescla vertical de l'aigua recarregada a diverses altures és important, de manera que la recàrrega estimada a partir del balanç de clorurs pot ser notablement sobrevalorada I cal fer-hi correccions. El mètode es pot comparar favorablement amb els altres mètodes per a avaluar la recàrrega, encara que cadascun proporciona estimacions de la recàrrega diferents, que s'han de considerar en el context apropiat de lloc I temps.%The measurement of the atmospheric chloride deposition on land allows the estimation of long-term average aquifer recharge when the average chloride content in the recharge water is known. This is a well-established, simple method, although not exempt from theoretical and practical difficulties. In spite of its potential, it is seldom applied. Under favorable circumstances, the results are reliable and the associated uncertainty can be determined. The chloride content of recharge water can be obtained from sampling the top of the water table. The method and its improvements have been the subject of extensive research and it has been applied to several aquifers throughout Spain, in the context of applied research projects and in doctoral thesis studies, by the Groundwater Hydrology Group of the Geoengineering Department of the Technical University of Catalonia (UPC). For aquifers discharging into springs or developed by means of deep wells, the vertical mixing of groundwater recharged at different altitudes is important. Thus, the chloride content may overestimate aquifer recharge and corrections are needed. In the present study the method has been developed and improved. It compares favorably to other methods, although it yields diverse recharge estimations that have to be referred to the appropriated site and time.
机译:在稳态下,如果已知补给水中平均氯含量,则从长远来看,大气中氯化物在地面上的沉积可以估算含水层中的平均补给量。这是一种简单的众所周知的方法,但尽管经常没有发挥其潜力,但并非没有理论和实践上的困难。在有利的情况下,所获得的结果是可靠的,并使我们能够估计不确定性。补充水的氯含量可以从地下水位上部的采样中得出。该方法及其改进一直是西班牙各个水层和整个西班牙研究和应用的目标,是与西班牙水文局地下水文小组有关的应用研究项目和博士学位论文的一部分。加泰罗尼亚政治大学(UPC)的地形工程,制图和地球物理学。对于排入泉水或被深井开采的含水层,在不同高度补给的水的垂直混合非常重要,因此,从氯化物平衡中估算出的补给量可能会大大高估。 -更正。该方法可以与其他评估补给的方法进行比较,尽管每种方法都提供不同的补给估算值,必须在适当的位置和时间范围内考虑该估算值。%如果已知补给水中的平均氯含量,则土地可以估算长期平均含水层补给量。这是一种公认​​的简单方法,尽管不能免除理论和实践上的困难。尽管具有潜力,但很少应用。在有利的情况下,结果是可靠的,并且可以确定相关的不确定性。补给水中的氯化物含量可通过对地下水位顶部进行采样获得。该方法及其改进已成为广泛研究的主题,在西班牙应用技术研究项目和博士论文研究中,该方法已应用于西班牙的数个含水层,由西班牙技术大学地球工程系的地下水水文学小组负责。加泰罗尼亚(UPC)。对于排入泉水或通过深井开采的含水层,在不同高度补给的地下水的垂直混合非常重要。因此,氯化物含量可能高估了含水层的补给,需要进行校正。在本研究中,该方法已得到开发和改进。尽管可以得出各种补给估算值,但必须参考适当的地点和时间,因此与其他方法相比,它具有优势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号