首页> 外文期刊>Mitsubishi Heavy Industries Technical Review >Study on Noise from Air-Cooled Heat Exchanger by Compressor Pulsation
【24h】

Study on Noise from Air-Cooled Heat Exchanger by Compressor Pulsation

机译:压缩机脉动的风冷换热器噪声研究

获取原文
获取原文并翻译 | 示例
       

摘要

Noise problems caused by gas pulsations in the tubes of air-cooled heat exchangers have become more serious with the advance of the techniques for fan noise reduction in air conditioners. The prediction and the reduction of noise caused by the gas pulsations were investigated. The predictions of sound radiation and tube vibrations of air-cooled heat excliangers were carried out. using Statistical Energy Analysis (SEA). The value of the loss factor of gas pulsations becomes high, when two-phase flows occur in the tubes. Therefore, the values were investigated and used for prediction. For the exciting forces, the forces of pressure at U bends and in straight pipes of heat exchangers were used. Air conditioners developed using the above method generate very low noise levels and they have been well received by customers.
机译:随着用于空调的风扇降噪技术的发展,由空气冷却的热交换器的管中的气体脉动引起的噪声问题变得更加严重。研究了由气体脉动引起的噪声的预测和降低。进行了空气冷却的热准分子的声辐射和管振动的预测。使用统计能量分析(SEA)。当在管中发生两相流动时,气体脉动的损失因子的值变高。因此,调查了这些值并将其用于预测。对于激振力,使用了U形弯曲处和热交换器的直管中的压力。使用上述方法开发的空调产生的噪声水平非常低,因此受到了客户的好评。