A flow injection hydride generation graphite furnace atomic absorption spectrometric (FI-HG-GFAAS) method was applied to the determination of Se in Se-doped and undoped cereals and bakery products. For the purpose of doping, the soils used for the cultivation of the cereals were dosed with Se-doped foliar fertilizers. The samples were dissolved in a mixture of HNO3 and H2O2 solutions using microwave-assisted digestion. The decomposition of H2Se generated from the sample solutions and the trapping of elemental Se were performed at a temperature of 300 °C on an Ir-pretreated integrated graphite platform of a transversally heated graphite atomizer (THGA). For release of the trapped Se within a fairly short atomization time (5 s), an atomization temperature of 2200 °C was observed to be optimal. The overall efficiency of hydride generation, transport and trapping was ∼86%.
机译:流动注射氢化物发生石墨炉原子吸收光谱法(FI-HG-GFAAS)用于测定硒和非硒谷物和焙烤食品中的硒。出于掺杂的目的,向用于谷物种植的土壤中添加了掺硒的叶面肥料。使用微波消解将样品溶解在HNO3 和H2 O2 的混合物中。由样品溶液产生的H2Se的分解和元素硒的捕集是在300°C的温度下,在横向加热的石墨雾化器(THGA)的Ir预处理的集成石墨平台上进行的。为了在相当短的雾化时间内(5 s)释放被捕获的硒,观察到最佳雾化温度为2200°C。氢化物生成,运输和捕集的总效率约为86%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号