摘要

A simple and sensitive cloud point extraction method has been developed for the preconcentration of ultra-trace amounts of gold as a prior step to its determination by electrothermal atomic absorption spectrometry. It is based on the extraction of gold in hydrochloric acid medium using the non-ionic surfactant polyethyleneglycolmono-p-nonylphenylether (PONPE 7.5) without adding a chelating agent. The preconcentration of a 50 mL sample solution was thus enhanced by a factor of 200. The resulting calibration graph was linear in the range of 10–200 ng L?1 with a correlation coefficient of 0.9993. The limit of detection (3s) obtained under optimal conditions was 2.0 ng L?1. The relative standard deviation for 10 replicate determinations at a 100 ng L?1 Au level was 3.6%. The method was applied to the ultra-trace determination of gold in water and copper samples.
机译:已经开发了一种简单灵敏的浊点提取方法,用于超痕量金的预浓缩,这是通过电热原子吸收光谱法测定其之前的步骤。它基于使用非离子型表面活性剂聚乙二醇单对壬基苯基醚(PONPE 7.5)在盐酸介质中提取金而无需添加螯合剂的原理。因此,将50 mL样品溶液的预浓缩提高了200倍。得到的校准图在10–200 ng L?1 范围内呈线性,相关系数为0.9993。在最佳条件下获得的检出限(3s)为2.0 ng L?1 。在100 ng L?1 Au浓度下进行10次重复测定的相对标准偏差为3.6%。该方法用于水和铜样品中金的超痕量测定。