首页> 外文期刊>Materials Chemistry and Physics >Shear bond strength and characterization of interfaces between electroformed gold substrates and porcelain
【24h】

Shear bond strength and characterization of interfaces between electroformed gold substrates and porcelain

机译:电铸金基底和瓷器之间的剪切粘结强度和界面特性

获取原文
获取原文并翻译 | 示例
       

摘要

This study aimed to determine the effects of two different sandblasting conditions on the shear bond strength between electroformed Au substrates and porcelain, and characterize the interface between the Au substrate and porcelain. Electroformed Au specimens, 0.3 mm thick with a cap-like shape were prepared. The prepared specimens were then divided into two different groups and each group was sandblasted with a different size of alumina grains (100 or 250 μm) prior to dental porcelain application. Bonded specimens from each group were subjected to shear testing. After debonding, the fracture mode was analyzed by optical microscopy and SEM-EDX. One intact bonded specimen from each group was metallographically prepared to characterize the interfacial bonding by SEM-EDX and area scan analysis. The shear bond strength values (MPa) and standard deviations were 8.2 ± 1.8 and 9.1 ± 2.7 for the samples blasted with 100 and 250 nm alumina particles, respectively. No statistically significant difference was found between the two groups. In addition, no differences in fracture mode were found between the two groups. Qualitative analysis showed that, surprisingly, the Au substrate contained O, N, and P which might be related to the Au-sulfite electrolyte used in electroforming. As expected, the retained porcelain comprised Si, 0, Al, Ca, Na and K. Mutual diffusion of Au, P, Si, Na, K and 0 without concentration gradients was found at the interface. Mutual ionic diffusion at the interface between ceramics and electroformed Au substrates (as opposed to mechanical interlocking) seems to be the most possible factor contributing to Au-ceramic bonding.
机译:本研究旨在确定两种喷砂条件对电铸Au基底与瓷器之间的剪切粘结强度的影响,并表征Au基底与瓷器之间的界面。制备厚度为0.3 mm,呈帽状的电铸Au样品。然后将准备好的标本分为两组,每组在应用牙科瓷器之前先用不同尺寸的氧化铝颗粒(100或250μm)进行喷砂处理。每组的粘结样品都进行了剪切测试。脱粘后,通过光学显微镜和SEM-EDX分析断裂模式。通过金相学制备每组一个完整的粘结试样,以通过SEM-EDX和面积扫描分析表征界面粘结。用100和250 nm氧化铝颗粒喷砂处理的样品的剪切粘结强度值(MPa)和标准偏差分别为8.2±1.8和9.1±2.7。两组之间无统计学差异。另外,两组之间在骨折模式上没有差异。定性分析表明,令人惊讶的是,Au基体中含有O,N和P,这可能与电铸中使用的亚硫酸金电解质有关。如预期的那样,保留的瓷器包含Si,0,Al,Ca,Na和K。在界面处发现Au,P,Si,Na,K和0的相互扩散而没有浓度梯度。陶瓷和电铸Au衬底之间的界面处的离子相互扩散(与机械互锁相反)似乎是促成Au-陶瓷键合的最可能因素。

著录项

  • 来源
    《Materials Chemistry and Physics》 |2013年第3期|825-833|共9页
  • 作者单位

    Dental Biomaterials Research and Development Chair, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia,Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia;

    Aesthetic and Prosthesis Dental Laboratory, Private Practice, Athens, Greece;

    Dental Biomaterials Research and Development Chair, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia,Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, Saudi Arabia;

    Dental Biomaterials Research and Development Chair, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia,Department of Mechanical Engineering, College of Engineering, King Saud University, Riyadh, Saudi Arabia;

    Department of Biomaterials, School of Dentistry, University of Athens, Athens, Greece;

    Dental Biomaterials Research and Development Chair, College of Dentistry, King Saud University, P.O. Box 60169, Riyadh 11545, Saudi Arabia,Department of Biomaterials, School of Dentistry, University of Athens, Athens, Greece;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Biomaterials; Coatings; Electron microscopy; Energy dispersive analysis of X-rays (EDS);

    机译:生物材料;涂料;电子显微镜;X射线(EDS)的能量色散分析;