...
首页> 外文期刊>Lasers in Medical Science >Scanning electron microscopy investigation of PMMA removal by laser irradiation (Er:YAG) in comparison with an ultrasonic system and curettage in hip joint revision arthroplasty
【24h】

Scanning electron microscopy investigation of PMMA removal by laser irradiation (Er:YAG) in comparison with an ultrasonic system and curettage in hip joint revision arthroplasty

机译:扫描电镜观察激光辐照去除PMMA(Er:YAG)与超声系统的比较以及刮除髋关节翻修置换术

获取原文
获取原文并翻译 | 示例

摘要

The cement often left in the femur socket during hip joint revision arthroplasty is usually removed by curettage. Another method for removing the cement is to use an ultrasonic system, and yet another alternative may be to use a laser system. The aim of these investigations was to determine the pulse rate and pulse energy of the Er:YAG laser for sufficient cement ablation. We also compared the results obtained using the laser with those obtained using an ultrasonic device or curettage by histological and scanning electron microscopy (SEM) investigation of the border zone between the polymethyl methacrylate (PMMA) and unfixed specimens of femoral bone. Therefore we prepared 30 unfixed human femur stems after hip joint replacement and prepared ten sagittal sections from each femur stem (in total 300 sections). Of these 300 specimens, 180 were treated with the Er:YAG laser, 60 with the ultrasonic system and 60 by curettage. The high pulse energy of 500 mJ and a pulse rate of 4 Hz provided the highest PMMA ablation rate, although the boundary surface between PMMA and femoral bone was not as fine-grained as found in samples treated at 15 Hz and 250 mJ. However, the treatment time for the same cement ablation rate with the latter settings was twice that at 4 Hz and 500 mJ. Compared to the boundary surfaces treated with the ultrasonic device or curettage, the laser-treated samples had a more distinct undifferentiated boundary surface between PMMA and femoral bone. After development of the Er:YAG-laser to provide higher pulse energies, it may in the future be an additional efficient method for the removal of PMMA in revision arthroplasty. The Er:YAG laser should be combined with an endoscopic and a rinsing suction system so that PMMA can be removed from the femoral shaft under direct vision.
机译:髋关节翻修术中常留在股骨窝中的骨水泥通常通过刮除术去除。去除水泥的另一种方法是使用超声系统,而另一种替代方法可以是使用激光系统。这些研究的目的是确定Er:YAG激光的脉冲频率和脉冲能量,以进行足够的烧蚀。我们还比较了使用激光获得的结果与使用超声设备或刮宫术通过组织学和扫描电子显微镜(SEM)对聚甲基丙烯酸甲酯(PMMA)与未固定的股骨标本之间的边界区域进行研究的结果。因此,我们在髋关节置换后准备了30个未固定的人股骨茎,并从每个股骨茎中准备了十个矢状切面(总共300个切面)。在这300个标本中,有180个用Er:YAG激光治疗,60个用超声系统治疗,60个通过刮宫术治疗。 500 PJ的高脉冲能量和4 Hz的脉冲频率提供了最高的PMMA消融率,尽管PMMA与股骨之间的边界表面不如在15 Hz和250 mJ处理的样品中发现的那样细。但是,对于相同的水泥烧蚀速率,后一种设置的处理时间是4 Hz和500 mJ时的两倍。与用超声装置或刮除术处理过的边界表面相比,经激光处理的样品在PMMA和股骨之间具有更明显的未分化边界表面。开发Er:YAG激光以提供更高的脉冲能量后,将来可能会成为翻修置换术中去除PMMA的另一种有效方法。 Er:YAG激光应与内窥镜和冲洗抽吸系统结合使用,以便可以在直视下从股骨干去除PMMA。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号