首页> 外文期刊>KSCE journal of civil engineering >Experimental Evaluation of Vibration Response of External Post-Tensioned Tendons with Corrosion
【24h】

Experimental Evaluation of Vibration Response of External Post-Tensioned Tendons with Corrosion

机译:外部后张筋腐蚀的振动响应的实验评估

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study investigates the vibration responses of external post-tensioned (PT) tendons based on experimental data. The vibration signals measured from four large-scale external post-tensioned tendon specimens subjected to localized corrosion until severe level of damage were accumulated. A series of impact tests was conducted to measure lateral vibration signals and the variation in the tension was continuously monitored using a load cell. The acquired vibration signals were evaluated using an axially-tensioned beam model in which the properties were varied to reflect the loss of tension and the reduction in the bending stiffness caused by corrosion damage. A comparison between the experimental data and the analytical results indicates that the natural frequencies were shifted as the residual tension decreased but were influenced by corresponding grout damage in a limited range. As a result, the frequency response was not appreciably affected by the damage level and the tension remained as the primary structural parameter of the external PT tendon with damage.
机译:本研究基于实验数据研究了外部后张式(PT)肌腱的振动响应。从四个经受局部腐蚀直至严重损坏的大型外部后张预应力筋试样测量的振动信号得以积累。进行了一系列冲击测试以测量横向振动信号,并使用称重传感器连续监测张力的变化。使用轴向张紧的梁模型评估获取的振动信号,在该模型中,通过更改特性来反映张力损失和腐蚀损坏导致的弯曲刚度降低。实验数据与分析结果之间的比较表明,固有频率会随着残余张力的降低而发生变化,但会受到相应范围内灌浆损害的影响。结果,频率响应不受损伤程度的明显影响,并且张力仍然是具有损伤的外部PT肌腱的主要结构参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号