首页> 外文期刊>The Korean journal of chemical engineering >Examining the effects of velocity ratio of the pressurized flow to the main inlet flow on coagulants dispersion in pump diffusion mixer
【24h】

Examining the effects of velocity ratio of the pressurized flow to the main inlet flow on coagulants dispersion in pump diffusion mixer

机译:检查加压流与主入口流的速度比对泵扩散混合器中凝结剂分散的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study was conducted to evaluate the ratio of the pressurized flow to the main inlet flow, which has been considered one of the most important parameters for operating the pump diffusion mixer (PDM). Computational fluid dynamics (CFD) simulation was employed to evaluate the conventional operation rule of PDM and to propose a supplementary operating parameter and criterion. Test simulation of CFD was carried out for the 21 cases of flow ratio in a full scale PDM. The values of local velocity gradient were calculated in each case to analyze the simulation results in more detail. A wet test was conducted to verify CFD simulation results, which measures the factual coagulant dispersion distribution at a distance of 5.4 m from deflector. From results of both CFD simulation and wet test, the flow ratio was adequate as an operating parameter or criterion; also, the velocity ratio (dimensionless) of the pressurized flow to the main inlet was useful in predicting the performance of PDM. In addition, the injected coagulant could be dispersed evenly in overall cross section on the condition that the velocity ratio is at least over 20.
机译:进行这项研究是为了评估加压流量与主进口流量的比率,这已被认为是操作泵扩散混合器(PDM)的最重要参数之一。计算流体动力学(CFD)仿真用于评估PDM的常规操作规则,并提出补充的操作参数和准则。在全尺寸PDM中针对21种流量比率进行了CFD的测试模拟。分别计算局部速度梯度的值,以更详细地分析仿真结果。进行了湿法测试以验证CFD模拟结果,该结果测量了离偏转器5.4 m处的实际凝结剂分散分布。从CFD模拟和湿法试验的结果来看,流量比足以作为操作参数或标准。同样,到主入口的增压流的速度比(无量纲)也可用于预测PDM的性能。另外,在速度比至少大于20的条件下,注入的凝结剂可以在整个横截面上均匀地分散。

著录项

  • 来源
    《The Korean journal of chemical engineering》 |2011年第2期|p.519-526|共8页
  • 作者单位

    Water Research Center, K-water Institute, Korea Water Resources Corporation (K-water), 462-1, Jeonmin-dong, Yusung-gu, Daejeon 305-730, Korea;

    Water Research Center, K-water Institute, Korea Water Resources Corporation (K-water), 462-1, Jeonmin-dong, Yusung-gu, Daejeon 305-730, Korea;

    Water Research Center, K-water Institute, Korea Water Resources Corporation (K-water), 462-1, Jeonmin-dong, Yusung-gu, Daejeon 305-730, Korea;

    Water Research Center, K-water Institute, Korea Water Resources Corporation (K-water), 462-1, Jeonmin-dong, Yusung-gu, Daejeon 305-730, Korea;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    pump diffusion mixer; flow ratio; velocity ratio; computational fluid dynamics; wet test;

    机译:泵扩散混合器;流量比速度比计算流体动力学;湿试验;