首页> 外文期刊>Journal of texture studies >Comparison of two methods to categorize thickened liquids for dysphagia management in a clinical care setting context: The Bostwick consistometer and the IDDSI Flow Test. Are we talking about the same concept?
【24h】

Comparison of two methods to categorize thickened liquids for dysphagia management in a clinical care setting context: The Bostwick consistometer and the IDDSI Flow Test. Are we talking about the same concept?

机译:对临床护理环境中吞咽吞咽管理增稠液体的两种方法的比较:BOSTWICK Orderoper和IDDSI流程测试。我们在谈论同样的概念吗?

获取原文
获取原文并翻译 | 示例
           

摘要

The Bostwick consistometer and the International Dysphagia Diet Standardization Initiative (IDDSI) Flow Test are both proposed methods to measure and categorize thickened liquids for dysphagia management. The objectives were to: (a) compare the Bostwick consistometer reference values used in clinical settings and the IDDSI reference values of thickened liquids suggested for nutrition care plans in the management of dysphagia when measuring commercially available preprepared thickened liquids; (b) explore the relationship between the two methods; (c) assess the interchangeability; (d) document the intra-rater reliability. Preprepared thickened liquids (n = 32) were measured twice with the Bostwick consistometer and 3 times with the IDDSI Flow Test, using a rigorous methodology. A registered dietitian nutritionist and a registered nutrition and dietetic technician performed the measurements. The Pearson's correlation coefficient was calculated to explore the relationship between the two methods. Using a linear regression equation, back-calculations of the IDDSI Flow Test values were done, based on the experimental Bostwick results. Interchangeability was assessed by documenting the level of agreement between the results with a Bland and Altman graphical analysis. Intraclass correlation coefficients calculation and a Bland and Altman graphical analysis were performed to assess reliability. The strong correlation (r = -.93, p .001) between the IDDSI Flow Test and the Bostwick consistometer measurements suggests that they measure flow rate in a similar manner, but not exactly the same, as confirmed with the Bland and Altman graphical analysis. Thus, they produced results that are not interchangeable. However, both tests show excellent intra-rater reliability (ICC = 0.99) when using a rigorous methodology. Practical applications Thickened liquids are used to manage oropharyngeal dysphagia. Clinicians need to provide quality assurance/quality control (QA/QC) support in the selection or production of thickened liquids as well as staff training or patient education regarding these products. Methods and classification have been proposed to measure and categorize thickened liquids for dysphagia management, such as the line spread test, the Bostwick consistometer method, and the IDDSI Flow Test. Although empirical, these methods are more accessible to clinicians than viscometer or rheometer assessments. Clinicians need to understand the limitations of these techniques as neither appear to capture the full extent of consistency for potential beverages available on the market or produced in-house. In this article, we compare the Bostwick consistometer and the IDDSI Flow Test methods and classifications and propose a standard operating procedure in order to maximize the quality of results. We point out the large variations in consistency levels of commercial preprepared thickened liquids in light of the absence of evidence of clinical outcomes associated with either proposed methods or consistency classifications.
机译:Bostwick Orderomatish和国际吞咽饮食标准化倡议(IDDSI)流动试验都是提出的方法来测量和分类为吞咽困难管理的增稠液体。目标是:(a)比较临床环境中使用的Bostwick常量表参考值,并且在测量市售预准备的增稠液体时,在吞咽吞吐率管理中建议营养护理计划的增稠液体的IDDSI参考值; (b)探索两种方法之间的关系; (c)评估互换性; (d)记录帧内可靠性。使用严格的方法,用Bostwick常量计测量预准备的增稠液体(n = 32),并用IDDSI流量测试3次测量3次。注册营养师营养师和注册营养和饮食技师进行了测量。计算Pearson的相关系数是计算出两种方法之间的关系。使用线性回归方程,基于实验BOSTWICK结果,完成了IDDSI流量测试值的后计算。通过将结果与平淡和Altman图形分析记录结果之间的协议水平来评估互换性。脑内相关系数计算和平淡和Altman图形分析以评估可靠性。 IDDSI流测试和Bostwick常量计测量之间的强相关(r = -.93,p <,p <.001)表明它们以类似的方式测量流速,但与蓝色和altman图形证实确认分析。因此,它们产生了不可互换的结果。然而,两个测试在使用严格的方法时,均显示出优异的帧内帧内可靠性(ICC> = 0.99)。实用应用增稠液体用于管理口咽吞咽困难。临床医生需要提供质量保证/质量控制(QA / QC)在选择或生产方面的增厚液体以及有关这些产品的员工培训或患者教育。已经提出了方法和分类来测量和分类增稠液体用于吞咽困难管理,例如线路调差测试,BOSTWICK vollector方法和IDDSI流程测试。虽然经验性,临床医生比粘度计或流变仪评估更易于临床。临床医生需要了解这些技术的局限性,似乎都没有捕获市场上可用或在内部生产的潜在饮料的全部一致性。在本文中,我们比较Bostwick Ventyometer和IDDSI流测试方法和分类,并提出标准操作程序,以最大限度地提高结果质量。我们指出了鉴于没有与拟议方法或一致性分类相关的临床结果的证据的证据,我们指出了商业预载增稠液体的一致性水平的大变化。

著录项

  • 来源
    《Journal of texture studies》 |2019年第2期|95-103|共9页
  • 作者单位

    Univ Sherbrooke Fac Med & Hlth Sci Ctr Rech Charles Le Moyne Saguenay Lac St Jean In Sherbrooke PQ Canada|Ctr Integre Univ Sante & Serv Sociaux Saguenay La GRIMN Jonquiere PQ Canada;

    Assoc Nutritionnistes Experts Dysphagie Montreal PQ Canada;

    Prophagia Inc Laval PQ Canada;

    Univ Sherbrooke Fac Med & Hlth Sci Ctr Rech Charles Le Moyne Saguenay Lac St Jean In Sherbrooke PQ Canada|Ctr Integre Univ Sante & Serv Sociaux Saguenay La GRIMN Jonquiere PQ Canada;

  • 收录信息 美国《科学引文索引》(SCI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Bostwick consistometer; dysphagia; IDDSI flow test; reliability; thickened liquids;

    机译:Bostwick Orderomatish;吞咽困难;IDDSI流程测试;可靠性;增厚液体;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号