首页> 外文期刊>Journal of testing and evaluation >Evaluation of Guy Anchorage Strength in Clay for Transmission Tower
【24h】

Evaluation of Guy Anchorage Strength in Clay for Transmission Tower

机译:输电塔黏土人锚固强度评价

获取原文
获取原文并翻译 | 示例
       

摘要

Due to the growth of the economy in Thailand, the electricity transmission system must be regularly maintained so that electricity is effectively and safely distributed for uses in daily life and industries. Natural disasters often cause damage to transmission towers. In addition, some damage has occurred due to vandalisms and soil excavations near transmission towers. Foundation scouring and tilting typically occur at transmission towers. In practice, repair of damage to a transmission tower typically begins with transferring the foundation pressure of the damaged tower to other firm foundation soil using a guy fixed to a guy anchor. The transmission tower is then restored to its original condition. In this study, a series of field anchorage strength tests were performed in the Bangkok metropolitan region which is well-known for its very soft to soft clay deposits. Additionally, Kunzelstab penetration tests were performed to evaluate the undrained shear strengths of the clay with depth at the test locations. The measured ultimate anchorage strengths were then compared with values estimated theoretically on the basis of measured undrained shear strengths. The measured values were found to be approximately 70 % of the theoretical values. This was probably due to the clay disturbance caused by anchor installation. Based on this fact, the ultimate anchorage strengths were then estimated for other clay conditions.
机译:由于泰国经济的增长,必须定期维护电力传输系统,以便有效,安全地分配电力以用于日常生活和工业。自然灾害通常会损坏输电塔。此外,由于输电塔附近的人为破坏和土方开挖,还造成了一些损害。地基冲刷和倾斜通常发生在输电塔上。在实践中,对输电塔的损坏的修复通常开始于使用固定在拉索锚上的拉索将受损塔的地基压力转移到其他牢固的基础土壤上。然后将传输塔恢复到其原始状态。在这项研究中,在曼谷大都市地区进行了一系列现场锚固强度测试,该地区以其非常柔软的粘土沉积而闻名。此外,还进行了Kunzelstab渗透试验,以评估在试验位置处随深度变化的粘土的不排水剪切强度。然后将测得的极限锚固强度与基于测得的不排水抗剪强度理论估算的值进行比较。发现测量值约为理论值的70%。这可能是由于锚固安装引起的粘土扰动。基于这一事实,然后估计了其他黏土条件下的极限锚固强度。

著录项

  • 来源
    《Journal of testing and evaluation》 |2013年第4期|564-570|共7页
  • 作者单位

    Dept. of Civil Engineering, Faculty of Engineering, King Mongkut's Univ. of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand;

    Assistant Head of Transmission Line Engineering Section, Transmission Line Maintenance Dept., Electricity Generating Authority of Thailand (EGAT);

    Dept. of Civil Engineering, Faculty of Engineering, King Mongkut's Univ. of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand;

    Dept. of Civil Engineering, Faculty of Engineering, King Mongkut's Univ. of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand;

    Dept. of Civil Engineering, Faculty of Engineering, King Mongkut's Univ. of Technology Thonburi, 126 Pracha Uthit Rd., Bang Mod, Thung Khru, Bangkok 10140, Thailand;

    Naka Engineering Co., Ltd., 80/73 Ramkhamhaeng 118, Ramkhamhaeng Rd., Saphan Sung, Bangkok 10240, Thailand;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    guy anchor; anchorage strength; transmission tower; field testing; Kunzelstab penetration test;

    机译:家伙锚锚固强度输电塔;现场测试;Kunzelstab渗透测试;