The ACI Building Code permits the use of the equivalent uniform bending moment diagram factor (C_m) for computing the effect of moment gradient, along the column height, caused by unequal column end moments. The concept of equivalent uniform moment diagram was introduced into design practice to eliminate the need for extensive calculations based on the solution to a differential equation. The expression currently used by the ACI Building Code is a simplified equation based on the elastic behavior of columns, and does not include the inelastic material behavior. This study was conducted to investigate the influence of different variables on C_m of slender, tied, rectangular composite columns in which steel shapes are encased in concrete and to examine existing expressions for C_m. Approximately, 11,000 square composite columns, each with a different combination of specified values of variables, were simulated. The columns studied were subjected to short-term ultimate loads and unequal end moments causing moment gradient in single curvature and double curvature bending about the major axis of the encased steel section. Two design C_m equations are proposed in this paper.
机译:ACI建筑规范允许使用等效的均匀弯矩图系数(C_m)来计算由不相等的柱端弯矩引起的沿柱高的弯矩梯度的影响。在设计实践中引入了等效均匀矩图的概念,以消除基于微分方程解的大量计算的需要。 ACI建筑规范当前使用的表达式是基于柱的弹性行为的简化方程,不包括非弹性材料行为。进行了这项研究,以研究不同变量对细长的,绑扎的矩形复合柱(钢形包裹在混凝土中)的C_m的影响,并检验C_m的现有表达式。大约模拟了11,000平方米的复合柱,每个柱具有指定的变量值的不同组合。所研究的圆柱承受短期极限载荷和不等的最终弯矩,从而导致围绕封闭钢截面的长轴以单曲率和双曲率弯曲的力矩梯度。本文提出了两个设计C_m方程。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号