首页> 外文期刊>Journal of Power Sources >Performance of polymer electrolyte membrane fuel cell (PEMFC) stacks Part I. Evaluation and simulation of an air-breathing PEMFC stack.
【24h】

Performance of polymer electrolyte membrane fuel cell (PEMFC) stacks Part I. Evaluation and simulation of an air-breathing PEMFC stack.

机译:聚合物电解质膜燃料电池(PEMFC)电池组的性能I.空气呼吸PEMFC电池组的评估和仿真。

获取原文
获取原文并翻译 | 示例
       

摘要

The performance of an air-breathing polymer electrolyte membrane fuel cell (PEMFC) stack was evaluated under different environmental conditions. The humidity of the surrounding air significantly affected the performance of the stack. When the humidity was less than l0/100 RH at 35deg. C, the stack lost almost 95/100 power. Acceptable operating temperature for the stack would be from 20 to 40deg. C for > 36/100 RH. An empirical equation was proposed to analyze the performance of the PEMFC stack instead of only for a single cell. The results calculated with the empirical equation are excellently fitted to the experimental polarization curves at various humidity and temperatures. The impedance and Tafel slope of the stack both increase with decreasing either the environmental humidity or temperature.
机译:在不同的环境条件下评估了透气性聚合物电解质膜燃料电池(PEMFC)的性能。周围空气的湿度严重影响了烟囱的性能。当湿度在35度下小于10/100 RH时。 C,堆栈损失了几乎95/100的功率。烟囱可接受的工作温度为20至40度。 C> 36/100 RH。提出了一个经验方程来分析PEMFC堆栈的性能,而不是仅用于单个单元。用经验公式计算的结果与各种湿度和温度下的实验极化曲线非常吻合。堆叠的阻抗和塔菲尔斜率都随着环境湿度或温度的降低而增加。