首页> 外文期刊>Journal of power sources >Measurements of humidity and current distribution in a PEFC
【24h】

Measurements of humidity and current distribution in a PEFC

机译:PEFC中湿度和电流分布的测量

获取原文
获取原文并翻译 | 示例
           

摘要

Voltage decreases of polymer electrolyte fuel cells (PEFC) are affected by the relative humidity of the reaction gas inside the cells. A study was conducted to establish a method for measuring relative humidity and current distribution inside PEFC cells in order to identify the factors affecting the voltage decay of such fuel cells. The humidity distribution was measured using a humidity sensor for directly monitoring the relative humidity of the reaction gas flowing through the air flow channel of the cathode separator. The current distribution was measured directly by attaching a current sensor to the rib of the cathode separator. Typical results of relative humidity and current distribution are described and interpretations are discussed.
机译:聚合物电解质燃料电池(PEFC)的电压降低受电池内部反应气体的相对湿度影响。进行了一项研究以建立一种测量PEFC电池内部相对湿度和电流分布的方法,以便确定影响此类燃料电池电压衰减的因素。使用湿度传感器测量湿度分布,该湿度传感器用于直接监测流过阴极分离器的空气流动通道的反应气体的相对湿度。通过将电流传感器安装到阴极隔板的肋条上直接测量电流分布。描述了相对湿度和电流分布的典型结果,并讨论了解释。