摘要

A passive (air breathing) planar three-cell direct methanol fuel cell was designed, fabricated and tested. The design concepts for plates, current collectors, seals and membrane electrode assemblies are discussed in this paper. Testing of single cells and stacks with parallel and serial connections were carried out. The results show that a reliable areal power density of 8.6 mW cm~(-2) can be achieved at ambient temperature with passive operation. Stacks with a serial connection of the single cells gave significantly higher performance than a parallel connection. It was also identified that high electrical resistance was the dominant factor in reducing performance. The major causes of the high resistance were the stainless steel hardware used and poor contact between the electrode and current collector. Future work will involve material and design studies of current collectors and seals to minimize the electrical resistance, and architectural design studies to effectively utilize the heat generated to raise operation temperature.
机译:设计,制造和测试了无源(空气呼吸)平面三电池直接甲醇燃料电池。本文讨论了板,集电器,密封件和膜电极组件的设计概念。对具有并联和串行连接的单电池和电池堆进行了测试。结果表明,在环境温度下,通过被动操作可获得可靠的8.6 mW cm〜(-2)的面功率密度。具有单个单元的串行连接的堆栈比并行连接具有更高的性能。还确定高电阻是降低性能的主要因素。高电阻的主要原因是所使用的不锈钢硬件以及电极与集电器之间的接触不良。未来的工作将涉及集电器和密封件的材料和设计研究,以最大程度地减小电阻,以及建筑设计研究,以有效利用产生的热量来提高工作温度。