首页> 外文期刊>Journal of offshore mechanics and arctic engineering >Temperature Measurements in a Linear Generator and Marine Substation for Wave Power
【24h】

Temperature Measurements in a Linear Generator and Marine Substation for Wave Power

机译:线性发电机和船用变电站中用于波功率的温度测量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper analyzes temperature measurements acquired in the offshore operation of a wave energy converter array. The three directly driven wave energy converters have linear generators and are connected to a marine substation placed on the seabed. The highly irregular individual linear generator voltages are rectified and added on a common dc-link and inverted to 50 Hz to facilitate future grid-connection. The electrical power is transmitted to shore and converted to heat in a measuring station. The first results of temperature measurements on substation components and on the stator of one of the linear generators are presented based on operation in linear and in nonlinear damping. The results indicate that there might be some convective heat transfer in the substation vessel. If high power levels are extracted from the waves, this has to be considered when placing components in the substation vessel in order to avoid heating from neighboring components. The results also indicate that the temperature increase in the linear generator stator is very small. Failure due to excessive heating of the stator winding polyvinyl chloride cable insulation is unlikely to occur even in very energetic sea states. Should this conclusion be incorrect, the thermal conductivity between the stator and the hull of the wave energy converter could be enhanced. Another suggested alteration is to lower the resistive losses by reducing the linear generator current density.
机译:本文分析了在波能转换器阵列海上作业中获得的温度测量值。三个直接驱动的波能转换器具有线性发电机,并连接到位于海床上的海上变电站。对高度不规则的单个线性发电机电压进行整流,并添加到公共直流母线上,然后反相至50 Hz,以方便将来并网。电力在测量站中传输到岸上并转化为热量。基于线性和非线性阻尼的操作,给出了变电站组件和一个线性发电机的定子上温度测量的最初结果。结果表明,变电站容器中可能存在对流传热。如果从电波中提取了高功率水平,则在将组件放置在变电站容器中时必须考虑这一点,以避免相邻组件发热。结果还表明,线性发电机定子中的温度升高非常小。即使在非常活跃的海况下,也不会发生因定子绕组聚氯乙烯电缆绝缘层过热而导致的故障。如果该结论不正确,则可以提高波能转换器的定子与船体之间的热导率。另一个建议的更改是通过降低线性发电机电流密度来降低电阻损耗。

著录项

  • 来源
    《Journal of offshore mechanics and arctic engineering》 |2012年第2期|p.021901.1-021901.6|共6页
  • 作者单位

    Department Of Engineering Sciences, Division For Electricity, Uppsala University, Swedish Centre For Renewable Electric Energy Conversion, Box 534, Se-751 21 Uppsala, Sweden;

    Department Of Engineering Sciences, Division For Electricity, Uppsala University, Swedish Centre For Renewable Electric Energy Conversion, Box 534, Se-751 21 Uppsala, Sweden;

    Department Of Engineering Sciences, Division For Electricity, Uppsala University, Swedish Centre For Renewable Electric Energy Conversion, Box 534, Se-751 21 Uppsala, Sweden;

    Department Of Engineering Sciences, Division For Electricity, Uppsala University, Swedish Centre For Renewable Electric Energy Conversion, Box 534, Se-751 21 Uppsala, Sweden;

    Department Of Engineering Sciences, Division For Electricity, Uppsala University, Swedish Centre For Renewable Electric Energy Conversion, Box 534, Se-751 21 Uppsala, Sweden;

    Department Of Engineering Sciences, Division For Electricity, Uppsala University, Swedish Centre For Renewable Electric Energy Conversion, Box 534, Se-751 21 Uppsala, Sweden;

    Department Of Engineering Sciences, Division For Electricity, Uppsala University, Swedish Centre For Renewable Electric Energy Conversion, Box 534, Se-751 21 Uppsala, Sweden;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);