首页> 外文期刊>Journal of Mechanical Science and Technology >A biomechanical study of osteoporotic vertebral trabecular bone: The use of micro-CT and high-resolution finite element analysis
【24h】

A biomechanical study of osteoporotic vertebral trabecular bone: The use of micro-CT and high-resolution finite element analysis

机译:骨质疏松性椎骨小梁骨的生物力学研究:微CT和高分辨率有限元分析的使用

获取原文
获取原文并翻译 | 示例
           

摘要

Osteoporosis is one of the most dangerous skeletal diseases in relation to the highest fracture risk in vertebral bones. A considerable amount of work has been done to investigate the biomechanical characteristics of osteoporotic vertebral trabecular bone. Previous researchers studied the elastic characteristics using a micro-finite element (micro-FE) model, used to analyze realistic trabecular architectures in full detail, based on micro-computed tomography (μCT). Since osteoporotic compression fracture is closely associated with the mechanical characteristics of the vertebral trabecular bone and there were few micro-FE models to account for all of the elastic and plastic characteristics in vertebral trabecular bone, this study analyzed the effect of voxel resolution on the plastic characteristics as well as the elastic characteristics of three-dimensional (3D) osteoporotic lumbar trabecular bone models. Also, we evaluated the effect of specimen geometry on this problem. It has been reported that a cubic specimen with side length 6.5mm was suggested as standard specimens for the experimental test of trabecular bone. Current study examined whether or not the effect of the specimen geometry on the experimental test may be also applied to the simulated compression test of trabecular bone specimens. The experimental test employing the rapid prototyping (RP) technique and INSTRON test machine is performed to indirectly validate the results of the simulated compression test by micro-FE analysis. The review finished with the verification about the effects of the simulated compression test.
机译:骨质疏松症是与椎骨骨折风险最高相关的最危险的骨骼疾病之一。已经进行了大量工作来研究骨质疏松性椎骨小梁骨的生物力学特性。以前的研究人员使用微有限元(micro-FE)模型研究了弹性特性,该模型用于基于微计算机断层扫描(μCT)来详细分析现实的小梁结构。由于骨质疏松性压缩性骨折与椎骨小梁骨的力学特性密切相关,并且几乎没有微FE模型可以说明椎骨小梁骨的所有弹性和塑性特征,因此本研究分析了体素分辨率对塑料的影响(3D)骨质疏松性腰小梁模型的弹性特征和弹性特征。此外,我们评估了样品几何形状对这个问题的影响。据报道,建议将边长为6.5mm的立方体标本作为小梁骨实验测试的标准标本。当前的研究检查了样本几何形状对实验测试的影响是否也可以应用于小梁骨样本的模拟压缩测试。进行了使用快速原型(RP)技术和INSTRON测试机的实验测试,以通过micro-FE分析间接验证模拟压缩测试的结果。审查完成了关于模拟压缩测试效果的验证。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号