首页> 外文期刊>Journal of Infrared, Millimeter, and Terahertz Waves >Large Signal Analysis of the Michelson Interferometer with Gires-Tournois Interferometers in its Arms
【24h】

Large Signal Analysis of the Michelson Interferometer with Gires-Tournois Interferometers in its Arms

机译:臂上装有Gires-Tournois干涉仪的迈克尔逊干涉仪的大信号分析

获取原文
获取原文并翻译 | 示例
       

摘要

A mathematical model for the transfer function of the Michelson interferometer with Gires-Tournois interferometers in its arms is presented. The model, basically a sine-series function, can easily yield closed-form expressions for the amplitudes of the harmonic and intermodulation components of the output when the input is formed of large-amplitude multisinusoidal voltage. The special case of two-tone equal-amplitude input voltage is considered in detail. The results show that the third-order intermodulation component is always higher than the third-harmonic component. The results also show that the linearity of the Michelson interferometer with Gires-Tournois interferometers in its arms improves with the increase of the front mirror reflectivity. Moreover, the results show that the third-order intermodulation exhibits a minimum for relatively large values of the front mirror reflectivity. Furthermore, compared with the traditional Mach-Zehnder interferometer, the results show that a reduction of 15 dB in the third-order intermodulation can be achieved even for relatively small values of the front mirror reflectivity.
机译:提出了臂上装有Gires-Tournois干涉仪的迈克尔逊干涉仪传递函数的数学模型。当输入由大振幅多正弦电压形成时,该模型基本上是一个正弦序列函数,可以轻松得出输出的谐波和互调分量幅度的闭式表达式。详细考虑了两音等幅输入电压的特殊情况。结果表明,三阶互调分量始终高于三阶谐波分量。结果还表明,随着前视镜反射率的增加,迈克尔逊干涉仪臂中带有Gires-Tournois干涉仪的线性度得到改善。而且,结果表明,对于较大的前镜反射率值,三阶互调表现出最小值。此外,与传统的Mach-Zehnder干涉仪相比,结果表明,即使前镜反射率的值相对较小,也可以将三阶互调降低15 dB。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号