首页> 外文期刊>Journal of Hazardous Materials >Electrochemical oxidation of stabilized landfill leachate on DSA electrodes
【24h】

Electrochemical oxidation of stabilized landfill leachate on DSA electrodes

机译:DSA电极上稳定垃圾填埋场渗滤液的电化学氧化

获取原文
获取原文并翻译 | 示例

摘要

The electrochemical oxidation of stabilized landfill leachate with 2960 mgL~(-1) chemical oxygen demand (COD) over a Ti/IrO_2-RuO_2 anode was investigated in the presence of HClO_4 as the supporting electrolyte. Emphasis was given on the effect of electrolysis time (up to 240 min) and temperature (30, 60 and 80℃), current density (8,16 and 32mAcm~(-2)), initial effluent's pH (0.25,3,5 and 6), HClO_4 concentration (0.25 and 1 M) and the addition of NaCl (20 and l00mM) or Na_2SO_4 (20 mM) as source of extra electrogenerated oxidants on performance; the latter was evaluated regarding COD, total carbon (TC), total phenols (TPh) and color removal. Moreover, the anode was studied by scanning electron microscopy and cyclic voltammetry. The main parameters affecting the process were the effluent's pH and the addition of salts. Treatment for 240 min at 32mAcm~(-2) current density, 80 ℃ and the pH adjusted from its inherent value of 0.25 (i.e. after the addition of HC1O_4) to 3 yielded 90% COD, 65% TC and complete color and TPh removal at an electricity consumption of 35 kWh kg~(-1) COD removed. Comparable performance (i.e. 75% COD reduction) could be achieved without pH adjustment but with the addition of 100 mM NaCl consuming 20 kWh kg~(-1) COD removed.
机译:以HClO_4为辅助电解质,研究了Ti / IrO_2-RuO_2阳极上2960 mgL〜(-1)化学需氧量(COD)对稳定垃圾渗滤液的电化学氧化作用。重点讨论了电解时间(长达240分钟)和温度(30、60和80℃),电流密度(8,16和32mAcm〜(-2)),初始流出物的pH(0.25、3、5)的影响。 6)浓度为HClO_4(0.25和1 M),并添加NaCl(20和100mM)或Na_2SO_4(20 mM)作为性能上多余的电氧化剂的来源;对后者进行了COD,总碳(TC),总酚(TPh)和脱色的评估。此外,通过扫描电子显微镜和循环伏安法研究了阳极。影响工艺的主要参数是废水的pH值和盐的添加。在32mAcm〜(-2)电流密度,80℃下处理240分钟,将pH从其固有值0.25(即在添加HC1O_4之后)调​​节至3,可产生90%的COD,65%的TC和完全去除色度和TPh电耗为35 kWh kg〜(-1)去除了COD。在不调节pH值但添加100 mM NaCl消耗20 kWh kg〜(-1)COD的情况下,可以实现可比的性能(即COD减少75%)。

著录项

  • 来源
    《Journal of Hazardous Materials 》 |2011年第3期| p.460-465| 共6页
  • 作者单位

    Department of Environmental Engineering, University of Padua, 35100 Padua, Italy;

    Department of Environmental Engineering, University of Padua, 35100 Padua, Italy;

    Department of Environmental Engineering, University of Padua, 35100 Padua, Italy;

    Department of Environmental Engineering, Technical University of Crete, 73100 Chania, Greece;

    Department of Environmental Engineering, Technical University of Crete, 73100 Chania, Greece;

    Department of Chemical Engineering, University ofPatras, 26504 Patras. Greece;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);