首页> 外文期刊>Journal of food protection >Validation of Receptor-Binding Assays To Detect Antibiotics in Goat's Milk
【24h】

Validation of Receptor-Binding Assays To Detect Antibiotics in Goat's Milk

机译:受体结合法检测羊奶中抗生素的验证

获取原文
获取原文并翻译 | 示例
       

摘要

The suitability of different receptor-binding assays to detect antibiotics in raw goat's milk was investigated. Detection capability of most P-lactams and tetracyclines assessed applying the Betastar Combo, the SNAP Betalactam, the SNAP Tetracycline, and the Twinsensor tests was at or below maximum residue limits established by European legislation. Regarding test specificity, cross-reactions with antibiotics other than β-lactams and tetracyclines were not found, and no false-positive results were obtained for the Betastar Combo and the SNAP tests when bulk samples of goat's milk were analyzed. For the Twinsensor test, the false-positive rate was 1%. The performance of the Betastar Combo and the SNAP tests was practically unaffected by the milk quality parameters using individual samples of goat's milk collected at points throughout the entire lactation period (false-positive rate, ≤5%). However, a larger number of positive results were obtained by the Twinsensor test in this type of milk sample (> 10%), especially in the last weeks of lactation. Interferences related to the use of the preservative azidiol were not observed in any case. Neither were any significant differences found in relation to the interpretation method (visual versus instrumental) applied. In general, the response of the Betastar Combo, SNAP, and Twinsensor tests was optimal for the analysis of bulk caprine milk; thus, they may be used to monitor milk for the presence of β-lactam and tetracycline residues in quality control programs.
机译:研究了不同受体结合试验对原山羊奶中抗生素检测的适用性。使用Betastar Combo,SNAP Betalactam,SNAP Tetracycline和Twinsensor测试评估的大多数P-内酰胺和四环素的检测能力达到或低于欧洲法规规定的最大残留限量。关于测试特异性,没有发现与除β-内酰胺类和四环素类以外的抗生素的交叉反应,并且在分析大量的山羊奶样品时,Betastar Combo和SNAP测试未获得假阳性结果。对于双传感器测试,假阳性率为1%。 Betastar Combo和SNAP测试的性能实际上不受牛奶质量参数的影响,使用整个哺乳期各点收集的山羊奶的单个样品(假阳性率,≤5%)使用牛奶质量参数即可。但是,通过双传感器测试,在这种类型的牛奶样品中获得了大量的阳性结果(> 10%),尤其是在哺乳的最后几周。在任何情况下都未观察到与使用防腐剂叠氮二醇有关的干扰。在所应用的解释方法(视觉还是工具)方面都没有发现任何显着差异。通常,Betastar组合,SNAP和Twinsensor测试的响应是分析大容量山羊奶的最佳选择;因此,它们可用于在质量控制程序中监测牛奶中β-内酰胺和四环素残留的存在。

著录项

  • 来源
    《Journal of food protection》 |2014年第2期|308-313|共6页
  • 作者单位

    Instituto de Ciencia y Tecnologia Animal, Universitat Politecnica de Valencia, Camino de Vera, s, 46071 Valencia, Spain;

    Instituto de Ciencia y Tecnologia Animal, Universitat Politecnica de Valencia, Camino de Vera, s, 46071 Valencia, Spain;

    Catedra de Biofisica,Facultad de Ciencias Veterinarias, Universidad Nacional del Litoral, R.P.L. Kreder 2805, 3080 Esperanza, Argentina;

    Catedra de Biofisica,Facultad de Ciencias Veterinarias, Universidad Nacional del Litoral, R.P.L. Kreder 2805, 3080 Esperanza, Argentina;

    Instituto de Ciencia y Tecnologia Animal, Universitat Politecnica de Valencia, Camino de Vera, s, 46071 Valencia, Spain;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

  • 入库时间 2022-08-17 23:25:11