首页> 外文期刊>Journal of food process engineering >Rapid detection of Salmonella Enteritidis and Escherichia coli using surface plasmon resonance biosensor.
【24h】

Rapid detection of Salmonella Enteritidis and Escherichia coli using surface plasmon resonance biosensor.

机译:使用表面等离振子共振生物传感器快速检测肠炎沙门氏菌和大肠杆菌。

获取原文
获取原文并翻译 | 示例
           

摘要

The Biacore surface plasmon resonance (SPR)-based biosensor was used to detect Salmonella enterica serovar Enteritidis and E. coli in spiked skim milk using specific antibodies. The optical SPR biosensor registers changes in the refractive index binding of the analyte (bacteria) to the ligand (antibody) on the gold-coated sensor chip surface. Immobilized protein A-captured specific antibodies were used to detect the bacteria in less than an hour. The reaction was found to be specific, and the limits of detection of the assay were found to be 25 cfu/ml for E. coli and 23 cfu/ml for Salmonella. The findings indicate that the antibody-prepared biosensor was specific to the target of interest, and non cross-reactive to the nontarget bacteria with high specificity comparable with that of the fibre-optic biosensor. The results demonstrate the potential of using the SPR-based Biacore biosensor for the detection of E. coli and Salmonella in foods such as milk. The biosensor is sensitive, specific, and rapid allowing real-time detection of the pathogens..
机译:基于Biacore表面等离振子共振(SPR)的生物传感器用于使用特异抗体检测加标脱脂牛奶中的肠炎沙门氏菌血清肠炎沙门氏菌和大肠杆菌。光学SPR生物传感器记录镀金传感器芯片表面上分析物(细菌)与配体(抗体)的折射率结合变化。固定化的蛋白A捕获的特异性抗体可在不到一个小时的时间内检测出细菌。发现该反应是特异性的,并且该测定的检测限对于大肠杆菌为25 cfu / ml,对于沙门氏菌为23 cfu / ml。这些发现表明,抗体制备的生物传感器对目标靶具有特异性,并且与非靶细菌具有非交叉反应性,具有与光纤生物传感器相当的高特异性。结果表明,使用基于SPR的Biacore生物传感器检测牛奶等食品中的大肠杆菌和沙门氏菌的潜力。该生物传感器灵敏,特异且快速,可以实时检测病原体。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号