首页> 外文期刊>Journal of Energy Resources Technology >Energy economy with a variable speed drive in an oxygen trim controlled boiler house
【24h】

Energy economy with a variable speed drive in an oxygen trim controlled boiler house

机译:在氧气调节控制的锅炉房中通过变速驱动实现能源经济

获取原文
获取原文并翻译 | 示例
       

摘要

This paper investigates the potentional for energy saving in a boiler house that can be achieved through installing a variable speed drive (VSD) for the fan motor by including an oxygen trim control cycle. This investigation is carried out through surveys; energy saving calculations are based on experimental data. In particular, some unique energy saving measures and energy efficiency improvements in the boiler associated with the VSD system are analytically and experimentally studied. In this study, the relation between excess air ratio and boiler efficiency was investigated in a water tube boiler that has the capacity of producing 55 tons of steam per unit time at 245 degrees C and 20 bar pressure. The boiler combustion air is supplied from a fan driven by a 30 kW 1450 rpm induction motor. Since the fan motor running at nominal speed has supplied the same airflow rate, excess air amount and exhaust gas temperature were very high at low loads. The boiler efficiency was low due to thermal energy losses and also consequently led to electrical energy losses. After implementation of the VSD, stack temperature was reduced from 200 degrees C to 142 degrees C, so the boiler efficiency was increased about 2.5% and 8000 kWh of electrical energy were saved in a month. The energy losses associated with excess air rate and its cost to manufacturers are evaluated and quantified. An overview and analysis of such conservation measures, along with the potential energy and cost savings, the implementation cost, and simple payback period are also given.
机译:本文研究了锅炉房节能的潜力,可以通过为风机电机安装变速驱动器(VSD)(包括氧气调整控制循环)来实现。该调查是通过调查进行的;节能计算基于实验数据。特别是,通过分析和实验研究了与VSD系统相关的锅炉中一些独特的节能措施和能效改进。在这项研究中,研究了一种水管锅炉中过量空气比率与锅炉效率之间的关系,该水管锅炉在245摄氏度和20巴的压力下每单位时间可产生55吨蒸汽。锅炉燃烧空气由风扇驱动,风扇由30 kW 1450 rpm感应电动机驱动。由于以额定速度运行的风扇电机提供了相同的空气流量,因此在低负载下过量的空气量和废气温度很高。由于热能损失,锅炉效率低,因此也导致电能损失。 VSD实施后,烟囱温度从200摄氏度降低到142摄氏度,因此锅炉效率提高了约2.5%,一个月内节省了8000千瓦时的电能。评估和量化与过量空气消耗相关的能量损失及其对制造商的成本。还对此类保护措施进行了概述和分析,以及潜在的能源和成本节省,实施成本和简单的投资回收期。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号