首页> 外文期刊>Journal of Electronic Packaging >Application of Synchrotron Radiation X-Ray Microtomography to Nondestructive Evaluation of Thermal Fatigue Process in Flip Chip Interconnects
【24h】

Application of Synchrotron Radiation X-Ray Microtomography to Nondestructive Evaluation of Thermal Fatigue Process in Flip Chip Interconnects

机译:同步辐射X射线显微照相技术在倒装芯片互连热疲劳过程的无损评估中的应用

获取原文
获取原文并翻译 | 示例
           

摘要

New nondestructive inspection methods with high spatial resolution are expected to support the evaluation and enhancement of the reliability of microjoints on printed circuit boards. An X-ray microtomography system, the SP-μCT has been developed at the Super Photon ring-8 GeV (SPring-8), the largest synchrotron radiation facility in Japan. In this work, the SP-μCT was first applied to the nondestructive evaluation of thermal fatigue phenomena, namely microstructure evolution (i.e., phase growth) and microcrackpropagation, appearing in actual solder microbumps of flip chip interconnects due to thermal cyclic loading. In addition, a refraction-contrast imaging technique was simultaneously applied to visualize the fatigue cracks with an actual opening of less than 100 nm. The observed specimen has a flip chip structure joined by Sn-37wt%Pb eutectic solder bumps 150 μm in diameter. Consequently, the process of phase growth and crack propagation was determined via observation of consecutive computed tomography (CT) images obtained in the same plane of the same specimen. As the thermal cycle proceeded, remarkable phase growth was clearly observed, followed by the appearance of fatigue cracks in the corners of the interfaces between the solder bump and Cu pad. Moreover, the CT images also enabled us to evaluate the fatigue lifetime of the bumps, as follows. The lifetime to fatigue crack initiation was estimated by quantifying the increase in the phase growth. The crack propagation lifetime to failure was then determined by measuring the average crack propagation rate. Such results have not been obtainable at all by X-ray CT systems for industrial use and demonstrate the possibility of nondestructive inspection by a synchrotron radiation X-ray microtomography system.
机译:新的具有高空间分辨率的非破坏性检查方法有望支持评估和增强印刷电路板上微接头的可靠性。 SP-μCT是一种X射线显微断层照相系统,是日本最大的同步加速器辐射设施Super Photon ring 8 GeV(SPring-8)开发的。在这项工作中,SP-μCT首先用于热疲劳现象的无损评估,即由于热循环载荷而在倒装芯片互连的实际焊料微凸点中出现的微结构演变(即相生长)和微裂纹扩展。此外,同时应用了折射对比成像技术以可视化实际开孔小于100 nm的疲劳裂纹。观察到的样品具有倒装芯片结构,该结构由直径为150μm的Sn-37wt%Pb共晶焊料凸块连接。因此,通过观察在同一样品的同一平面上获得的连续计算机断层扫描(CT)图像,确定了相发展和裂纹扩展的过程。随着热循环的进行,可以清楚地观察到明显的相增长,随后在焊料凸点和Cu焊盘之间的界面角处出现疲劳裂纹。此外,CT图像还使我们能够如下评估凸起的疲劳寿命。疲劳裂纹萌生的寿命通过量化相生长的增加来估计。然后通过测量平均裂纹扩展速率来确定裂纹扩展至失效的寿命。此类结果根本无法通过工业用X射线CT系统获得,并且证明了通过同步辐射X射线显微断层照相系统进行无损检查的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号