首页> 外文期刊>Journal of dairy science >Thresholds of whole-blood p-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia
【24h】

Thresholds of whole-blood p-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia

机译:用电子手持设备测量全血对羟基丁酸和葡萄糖浓度的阈值,以识别绵羊高酮血症

获取原文
获取原文并翻译 | 示例
       

摘要

Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xceed (PX; Abbott Diabetes Care Inc., Abbott Park, IL) to detect hyperketonemia in ewes. An additional objective of this study was to evaluate the agreement between samples obtained by minimal invasive venipuncture of an ear vein and measurements of whole-blood samples from the jugular vein (vena jugularis, v. jug.). Blood samples taken from the v. jug. were collected from 358 ewes on 4 different farms. These samples and a blood drop obtained from an ear vein were analyzed simultaneously on farm with the PX. For method comparison, the samples obtained from the v. jug. were also analyzed by standard methods, which served as the gold standard at the Central Laboratory of the University of Veterinary Medicine Vienna, Austria. The correlation coefficients between the serum BHBA concentration and the concentrations measured with the hand-held meter in the whole blood from an ear vein and the v. jug. were 0.94 and 0.96, respectively. The correlation coefficients of plasma and whole-blood glucose concentration were 0.68 for the v. jug. and 0.47 for the ear vein. The mean glucose concentration was significantly lower in animals classified as hyperketonemic (BHBA >1.6 mmol/L) compared with healthy ewes. Whole-blood concentrations of BHBA and glucose measured with the PX from v. jug. showed a constant negative bias of 0.15 mmol/L and 8.4 mg/ dL, respectively. Hence, a receiver operating characteristic analysis was performed to determine thresholds for the PX to detect hyperketonemia in ewes. This resulted in thresholds for moderate ketosis of BHBA concentrations of 0.7 mmol/L in blood from an ear vein and the v. jug. Cutoffs of 1.0 mmol/L (ear vein) and 1.1 mmol/L (v. jug.) BHBA were determined to detect animals at greater risk to develop severe hyperketonemia. Applying these thresholds, excellent test characteristics, with sensitivities of 1.00 for both samples and specificities of 0.98 for the ear vein and 0.97 for the v. jug. were determined. These results demonstrate that the PX is a useful tool for detection of hyperketonemia in ewes.
机译:代谢性疾病,尤其是高血钾症,在奶牛中非常常见。 β-羟基丁酸酯(BHBA)和葡萄糖的全血浓度可通过可商购的电子手持设备确定,该设备用于人类医学和检测奶牛的酮症。这项研究的目的是评估手持设备Precision Xceed(PX;伊利诺伊州阿伯特帕克的Abbott Diabetes Care Inc.)检测母羊高酮血症的适用性。这项研究的另一个目标是评估通过耳静脉的微创静脉穿刺获得的样本与来自颈静脉的全血样本的测量之间的一致性(vena jugularis,v。jug。)。从水罐中抽取的血液样本。是从4个不同农场的358头母羊中收集的。在农场使用PX同时分析了这些样品和从耳静脉获得的血滴。为了进行方法比较,从水罐中获得样品。还通过标准方法进行了分析,该方法在奥地利维也纳大学兽医学中心实验室中作为金标准。血清BHBA浓度与手持式仪表在耳静脉和壶中全血中测得的浓度之间的相关系数。分别为0.94和0.96。该水罐血浆与全血葡萄糖浓度的相关系数为0.68。耳静脉为0.47。与健康母羊相比,高酮血症动物(BHBA> 1.6 mmol / L)中的平均葡萄糖浓度显着降低。用VX水罐中的PX测量BHBA和葡萄糖的全血浓度。分别显示出0.15 mmol / L和8.4 mg / dL的恒定负偏压。因此,进行了接收器工作特性分析,以确定PX检测母羊高血钾的阈值。这导致了来自耳静脉和壶的血液中BHBA浓度为0.7 mmol / L的中度酮症的阈值。确定了1.0 mmol / L(耳静脉)和1.1 mmol / L(v。壶)BHBA的临界值,以检测出发生严重高酮血症风险更大的动物。应用这些阈值可实现出色的测试特性,两种样品的灵敏度均为1.00,耳静脉的灵敏度为0.98,v。壶的灵敏度为0.97。被确定。这些结果表明,PX是检测母羊高血钾症的有用工具。

著录项

  • 来源
    《Journal of dairy science》 |2014年第3期|1388-1399|共12页
  • 作者单位

    Clinical Unit for Herd Health Management for Ruminants, University Clinic for Ruminants, Department for Farm Animalsand Veterinary Public Health, University of Veterinary Medicine Vienna, 1210 Vienna, Austria;

    Clinical Unit for Herd Health Management for Ruminants, University Clinic for Ruminants, Department for Farm Animalsand Veterinary Public Health, University of Veterinary Medicine Vienna, 1210 Vienna, Austria;

    Central Clinical Pathology Unit, Department for Pathobiology, University of Veterinary Medicine Vienna, 1210 Vienna, Austria;

    Agricultural Research and Education Center Raumberg-Gumpenstein, 8952 Irdning (Styria), Austria;

    Clinical Unit for Herd Health Management for Ruminants, University Clinic for Ruminants, Department for Farm Animalsand Veterinary Public Health, University of Veterinary Medicine Vienna, 1210 Vienna, Austria;

    Clinical Unit for Herd Health Management for Ruminants, University Clinic for Ruminants, Department for Farm Animalsand Veterinary Public Health, University of Veterinary Medicine Vienna, 1210 Vienna, Austria;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    pregnancy toxemia; ketosis; hand-held meter; β-hydroxybutyrate;

    机译:妊娠毒血症酮症手持仪表β-羟基丁酸酯;
  • 入库时间 2022-08-17 23:23:53

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号