首页> 外文期刊>Journal of dairy science >Rapid assessment of bovine colostrum quality: How reliable are transmission infrared spectroscopy and digital and optical refractometers?
【24h】

Rapid assessment of bovine colostrum quality: How reliable are transmission infrared spectroscopy and digital and optical refractometers?

机译:快速评估牛初乳质量:透射红外光谱仪以及数字和光学折光仪的可靠性如何?

获取原文
获取原文并翻译 | 示例
       

摘要

The objectives of this study were to evaluate the performance of the transmission infrared (IR) spectro-scopic method and digital and optical Brix refractometers for measurement of colostral IgG concentration and assessment of colostrum quality of dairy cows. Colostrum samples (n = 258) were collected from Holstein cows on 30 commercial dairy farms in Nova Scotia and Newfoundland, Canada. Colostral IgG concentrations of 255 samples were measured by the reference radial immunodiffusion (RID) assay and IR spectroscopy. The Brix scores were determined on 240 of these samples using both the digital and optical Brix refractometers. Approximately half (48%) of the colostrum samples had RID IgG concentrations <50 g/L, which was the cut-point for poor quality. The correlation between RID and IR IgG concentrations was 0.88. The correlations between RID IgG concentration and Brix scores, as determined by the digital and optical refractometers, were 0.72 and 0.71, respectively. The optimal cutoff levels for distinguishing good- and poor-quality colostrum using IR spectroscopy, and digital and optical Brix refractometers were at 35 g/L and 23% Brix, respectively. The IR spectroscopy showed higher sensitivity (90%) and specificity (86%) than the digital (74 and 80%, respectively) and optical (73 and 80%, respectively) Brix refractometers for assessment of colostrum quality, as compared with RID. In conclusion, the transmission-IR spectroscopy is a rapid and accurate method for assessing colostrum quality, but is a laboratory-based method, whereas Brix refractometers were less accurate but could be used on-farm.
机译:这项研究的目的是评估透射红外(IR)光谱法以及数字和光学Brix折光仪用于测定初乳IgG浓度和评估奶牛初乳质量的性能。从加拿大新斯科舍省和纽芬兰的30个商业奶牛场的荷斯坦奶牛那里采集初乳样品(n = 258)。通过参考放射免疫扩散(RID)分析和红外光谱法测量了255个样品的结肠IgG浓度。使用数字和光学白利糖度折光仪在240个样本中确定白利糖度得分。大约一半(48%)的初乳样品的RID IgG浓度<50 g / L,这是质量较差的临界点。 RID和IR IgG浓度之间的相关性为0.88。通过数字折光仪和光学折光仪确定的RID IgG浓度和Brix评分之间的相关性分别为0.72和0.71。使用红外光谱,数字和光学白利糖度折光仪区分优质和劣质初乳的最佳截止水平分别为35 g / L和23%白利糖度。与RID相比,IR光谱显示出更高的灵敏度(90%)和特异性(86%)高于用于评估初乳质量的数字式Brix折射仪的数字(分别为74和80%)和光学(分别为73和80%)。总之,透射红外光谱法是一种快速,准确的评估初乳质量的方法,但它是一种基于实验室的方法,而白利糖度折光仪的准确性较低,但可以在农场使用。

著录项

  • 来源
    《Journal of dairy science》 |2017年第2期|1427-1435|共9页
  • 作者单位

    Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3,Infectious Diseases, Department of Animal Medicine, Faculty of Veterinary Medicine, Zagazig University, Zagazig City 44511,Sharkia Province, Egypt;

    Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3;

    Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3;

    Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3;

    Department of Health Management, Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada C1A 4P3;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    infrared spectroscopy; Brix refractometer; immunoglobulin G; radial immunodiffusion assay;

    机译:红外光谱白利糖度折光仪;免疫球蛋白G;放射免疫扩散测定;
  • 入库时间 2022-08-17 23:22:47

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号