ABSTRACT Technical note: Validation of the BHBCheck blood p-hydroxybutyrate meter as a diagnostic tool for hyperketonemia in dairy cows
首页> 外文期刊>Journal of dairy science >Technical note: Validation of the BHBCheck blood p-hydroxybutyrate meter as a diagnostic tool for hyperketonemia in dairy cows
【24h】

Technical note: Validation of the BHBCheck blood p-hydroxybutyrate meter as a diagnostic tool for hyperketonemia in dairy cows

机译:技术说明:BHBCheck血液对羟基丁酸血糖仪作为奶牛高血钾症诊断工具的验证

获取原文
获取原文并翻译 | 示例
       

摘要

ABSTRACTAccurate cow-side blood β-hydroxybutyrate (BHB) detection meters are valuable tools for rapid diagnosis of hyperketonemia. The main objective of this study was to compare the blood BHB measured in whole blood by the BHBCheck meter (PortaCheck, Moorestown, NJ) to a previously validated meter, Precision Xtra meter (Abbott Laboratories, Abbott Park, IL) and a colorimetric laboratory assay. Samples (n = 426) were collected from postpartum primiparous and multiparous Holstein cows (n = 79 cows) enrolled in 1 of 2 experiments (Exp) with different sampling schedules (Exp 1: n = 39 cows, 58 samples; Exp 2: n = 40 cows, 368 samples). In both Exp, whole-blood samples were collected from the coccygeal vessels after morning milking, before morning feeding. Blood samples were used immediately for BHB quantification via the BHBCheck meter and the Precision Xtra meter. Blood was also collected into evacuated tubes containing no additive (Exp 1) or potassium oxalate/sodium fluoride (Exp 2), which were centrifuged for serum or plasma separation and stored at −20°C for subsequent analysis. Laboratory quantification of BHB concentration was done by the BHB LiquiColor Assay (EKF Diagnostics-Stanbio, Boerne, TX; certified for serum and plasma). Data were analyzed by UNIVARIATE, CORR, FREQ, REG, and LOGISTIC procedures of SAS 9.4 (SAS Institute Inc., Cary, NC). Within this sample set, average parity was 3.3 lactations and DIM was 14 d. The proportion of samples classified as hyperketonemia (BHB ≥1.2 mmol/L) was 25, 28, and 31% as determined by the colorimetric assay, BHBCheck meter, and Precision Xtra meter, respectively. The correlation for BHBCheck meter BHB concentration compared with the colorimetric assay concentrations was r = 0.96, with a sensitivity of 91% and specificity of 93%. Correlation, sensitivity, and specificity of the Precision Xtra meter concentrations were 0.97, 98%, and 92%, respectively. Bland-Altman plots demonstrated minimal bias for both meters. Area under the receiver operator characteristic curve suggests adequate diagnostic accuracy of both meters. Overall, accuracy, sensitivity, and specificity of the BHBCheck meter was similar to the Precision Xtra meter and laboratory assay, indicating the BHBCheck meter is appropriate for use as a cow-side diagnostic test for hyperketonemia in dairy cows.
机译: 抽象 准确的牛侧血β-羟基丁酸酯(BHB)检测仪是快速诊断高酮血症的重要工具。这项研究的主要目的是将BHBCheck仪(新泽西州Moorestown的PortaCheck公司)与之前经过验证的Precision Xtra仪(伊利诺伊州Abbott Park的Abbott Laboratories,Abbott Laboratories公司)和比色实验室分析相比较,对全血中BHB 。样本(n = 426)是从2个实验(实验)中的1个以不同的采样时间表(实验1:n = 39头母牛,58个样本;实验2:n = 40头母牛,368个样本)。在这两个实验中,早晨挤奶后,早晨喂食前从尾骨血管中采集全血样品。血样立即通过BHBCheck仪和Precision Xtra仪用于BHB定量。还将血液收集到不含添加剂(Exp 1)或草酸钾/氟化钠(Exp 2)的真空管中,将其离心以分离血清或血浆,并保存在-20°C进行后续分析。 BHB浓度的实验室量化是通过BHB LiquiColor分析法(得克萨斯州Boerne的EKF Diagnostics-Stanbio;血清和血浆认证)完成的。通过UNIVARIATE,CORR,FREQ,REG和SAS 9.4(SAS Institute Inc.,Cary,NC)的LOGISTIC程序分析数据。在该样本集中,平均胎次为3.3泌乳,而DIM为14 d。通过比色测定,BHBCheck仪和Precision Xtra仪测定,被归类为高酮血症(BHB≥1.2mmol / L)的样品比例分别为25%,28%和31%。 BHBCheck仪BHB浓度与比色测定浓度的相关性为r = 0.96,灵敏度为91%,特异性为93%。 Precision Xtra仪表浓度的相关性,灵敏度和特异性分别为0.97、98%和92%。 Bland-Altman图显示了两种仪表的最小偏差。接收器操作员特征曲线下方的区域表明两个仪表的诊断准确性都很高。总体而言,BHBCheck测定仪的准确性,灵敏性和特异性与Precision Xtra测定仪和实验室测定相似,表明BHBCheck测定仪适合用作奶牛高酮血症的牛侧诊断测试。

著录项

  • 来源
    《Journal of dairy science》 |2018年第2期|1524-1529|共6页
  • 作者单位

    Department of Dairy Science, University of Wisconsin-Madison;

    Department of Dairy Science, University of Wisconsin-Madison;

    Department of Dairy Science, University of Wisconsin-Madison;

    Department of Dairy Science, University of Wisconsin-Madison;

    School of Veterinary Medicine, University of Wisconsin-Madison;

    Department of Dairy Science, University of Wisconsin-Madison;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    ketosis; cow-side diagnostic tool; transition cow;

    机译:酮症;牛侧诊断工具;过渡母牛;